Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Seong, Myeongsu -
dc.contributor.author Phillips, Zephaniah -
dc.contributor.author Phuong Minh Mai -
dc.contributor.author Yeo, Chaebeom -
dc.contributor.author Song, Cheol -
dc.contributor.author Lee, Kijoon -
dc.contributor.author Kim, Jae Gwan -
dc.date.available 2017-07-05T08:46:36Z -
dc.date.created 2017-04-10 -
dc.date.issued 2016-02 -
dc.identifier.issn 1083-3668 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/2298 -
dc.description.abstract A combined diffuse speckle contrast analysis (DSCA)-near-infrared spectroscopy (NIRS) system is proposed to simultaneously measure qualitative blood flow and blood oxygenation changes in human tissue. The system employs an optical switch to alternate two laser sources at two different wavelengths and a CCD camera to capture the speckle image. Therefore, an optical density can be measured from two wavelengths for NIRS measurements and a speckle contrast can be calculated for DSCA measurements. In order to validate the system, a flow phantom test and an arm occlusion protocol for arterial and venous occlusion were performed. Shorter exposure times (<1 ms) show a higher drop (between 50% and 66%) and recovery of 1/KS2 values after occlusion (approximately 150%), but longer exposure time (3 ms) shows more consistent hemodynamic changes. For four subjects, the 1/KS2 values dropped to an average of 82.1±4.0% during the occlusion period and the average recovery of 1/KS2 values after occlusion was 109.1±0.8%. There was also an approximately equivalent amplitude change in oxyhemoglobin (OHb) and deoxyhemoglobin (RHb) during arterial occlusion (max RHb=0.0085±0.0024 mM/DPF, min OHb=-0.0057±0.0044 mM/DPF). The sensitivity of the system makes it a suitable modality to observe qualitative hemodynamic trends during induced physiological changes. © 2016 Society of Photo-Optical Instrumentation Engineers (SPIE). -
dc.language English -
dc.publisher SPIE -
dc.title Simultaneous blood flow and blood oxygenation measurements using a combination of diffuse speckle contrast analysis and near-infrared spectroscopy -
dc.type Article -
dc.identifier.doi 10.1117/1.JBO.21.2.027001 -
dc.identifier.scopusid 2-s2.0-84959337223 -
dc.identifier.bibliographicCitation Journal of Biomedical Optics, v.21, no.2 -
dc.description.isOpenAccess FALSE -
dc.subject.keywordAuthor hemodynamics -
dc.subject.keywordAuthor blood flow -
dc.subject.keywordAuthor blood oxygenation -
dc.subject.keywordAuthor diffuse optics -
dc.subject.keywordAuthor diffuse speckle contrast analysis -
dc.subject.keywordAuthor near-infrared spectroscopy -
dc.subject.keywordPlus Hemodynamics -
dc.subject.keywordPlus NEAR-INFRARED SPECTROSCOPY -
dc.subject.keywordPlus OXIMETER -
dc.subject.keywordPlus Tomography -
dc.subject.keywordPlus VOLUME -
dc.subject.keywordPlus Blood Flow -
dc.subject.keywordPlus Blood Oxygenation -
dc.subject.keywordPlus Camera -
dc.subject.keywordPlus CEREBRAL-ISCHemIA -
dc.subject.keywordPlus Diffuse Optics -
dc.subject.keywordPlus Diffuse Speckle Contrast Analysis -
dc.subject.keywordPlus DYNAMICS -
dc.subject.keywordPlus EXPOSURE TIME -
dc.citation.number 2 -
dc.citation.title Journal of Biomedical Optics -
dc.citation.volume 21 -

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE