<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
  <channel>
    <title>Repository Collection: null</title>
    <link>https://scholar.dgist.ac.kr/handle/20.500.11750/16193</link>
    <description />
    <pubDate>Wed, 18 Nov 2026 19:38:19 GMT</pubDate>
    <dc:date>2026-11-18T19:38:19Z</dc:date>
    <item>
      <title>Multi-modality image fusion model of AFM-derived extracellular vesicles for NSCLC subtype diagnosis</title>
      <link>https://scholar.dgist.ac.kr/handle/20.500.11750/61097</link>
      <description>Title: Multi-modality image fusion model of AFM-derived extracellular vesicles for NSCLC subtype diagnosis
Author(s): Kim, Haeyoung; 박수현; Lee, Yoonhee; Ban, Jaepil; Koo, Gyogwon
Abstract: Non-small cell lung cancer (NSCLC) comprises multiple subtypes with distinct treatment strategies, making accurate subtype classification important. Therefore, this study aims to develop a multi-modality AFM-based deep learning model to improve NSCLC subtype diagnosis because extracellular vesicles (EVs) measured by atomic force microscopy (AFM) contain nanoscale biophysical information with diagnostic potential. The proposed model introduces two key components: (i) an intra-image feature extractor (IFE), which captures parameter-specific local and global dependencies, and (ii) a cross-image feature fusion module (CFFM), which mitigates domain mismatch among heterogeneous AFM parameters. Through three fusion strategies at the image, low-level feature, and high-level feature stages, the proposed model simultaneously learns intraparameter and inter-parameter relationships. The proposed model achieved an accuracy of 0.9245 and an area under the receiver operating characteristic curve (AUROC) of 0.9804, outperforming the AFM-based conventional state-of-the-art (SOTA) model by improvements of 0.1328 in accuracy and 0.0273 in AUROC. These results demonstrate that the proposed multi-modality fusion approach achieves superior diagnostic performance for AFM-based EV analysis. Furthermore, the proposed framework has the potential to be extended to AFM-based analysis of other cell types and diseases once large-scale datasets are secured. Code is released at https://github.com/sunh124/MMIF_Model_of_AFM-derived_EV.</description>
      <pubDate>Wed, 30 Sep 2026 15:00:00 GMT</pubDate>
      <guid isPermaLink="false">https://scholar.dgist.ac.kr/handle/20.500.11750/61097</guid>
      <dc:date>2026-09-30T15:00:00Z</dc:date>
    </item>
    <item>
      <title>Surface Tension-Guided Drop-and-Spread Inkjet Printing for Additive Fabrication of CNT Field-Effect Transistor Biosensors</title>
      <link>https://scholar.dgist.ac.kr/handle/20.500.11750/58997</link>
      <description>Title: Surface Tension-Guided Drop-and-Spread Inkjet Printing for Additive Fabrication of CNT Field-Effect Transistor Biosensors
Author(s): Park, Soohyun; Shin, Minhye; Kim, Eunui; Kang, Hongki; Lee, Yoonhee
Abstract: Carbon nanotube field-effect transistors (CNT FETs) are highly regarded in nanoelectronics for their superior electrical properties, yet their broader adoption in nanotechnology is hindered by challenges in scalable fabrication. These challenges are primarily related to controlling nanotube density and achieving consistent alignment at electrode junctions for large-scale production. Here, we present a novel in-place inkjet printing technique to construct CNT FETs, ensuring controlled numbers of connected CNTs. We print a series of pico-liter droplets of CNT ink onto prepatterned electrode arrays over a 4-in. silicon wafer, promoting additive device manufacturing without supplementary lithographic steps. Our technique leverages surface tension-driven flow, guiding droplet spread along electrodes, preventing unwanted CNT networks. This approach enhances manufacturing throughput and device yield and efficiently connects an individualized CNT array to electrodes with less than 10 tubes per device. Moreover, we demonstrate biosensing application by functionalizing devices with DNA aptamers, achieving serotonin detection at thresholds as low as 42 pM. This method establishes cost-efficient and simple micromanufacturing protocols essential for the mass production of CNT FET arrays, particularly beneficial for high-throughput bioassays.</description>
      <pubDate>Thu, 31 Jul 2025 15:00:00 GMT</pubDate>
      <guid isPermaLink="false">https://scholar.dgist.ac.kr/handle/20.500.11750/58997</guid>
      <dc:date>2025-07-31T15:00:00Z</dc:date>
    </item>
    <item>
      <title>Deep Learning-Based Classification of NSCLC-Derived Extracellular Vesicles Using AFM Nanomechanical Signatures</title>
      <link>https://scholar.dgist.ac.kr/handle/20.500.11750/58695</link>
      <description>Title: Deep Learning-Based Classification of NSCLC-Derived Extracellular Vesicles Using AFM Nanomechanical Signatures
Author(s): Park, Soohyun; Kim, Youngkyu; Kim, Jung-Hee; Kim, Haeyoung; Kim, Kwang-Youl; Kim, Eunjoo; Koo, Gyogwon; Lee, Yoonhee
Abstract: Nonsmall cell lung cancer (NSCLC) remains a leading cause of cancer-related mortality, with liquid biopsy emerging as a promising tool for noninvasive diagnostics. Extracellular vesicles (EVs) serve as molecular messengers of the tumor microenvironment, yet precise characterization methods remain limited. Using atomic force microscopy (AFM), we analyzed EVs from NSCLC subtypes (A549, PC9, PC9/GR) and nontumorigenic bronchial epithelial cells (BEAS-2B), revealing that A549-derived EVs exhibited significantly higher stiffness, likely due to KRAS mutation-associated lipid alterations. EGFR mutant EVs (PC9, PC9/GR) showed overlapping nanomechanical properties, correlating with their shared genetic background. To enhance classification, we implemented a DenseNet-based deep learning model for AFM image analysis, integrating nanomechanical and morphological features. This approach significantly improved diagnostic performance, achieving an AUC of 0.92, and notably, EVs from the A549 (KRAS mutant) cell line were classified with 96% accuracy. This study provides the first demonstration of the nanomechanical classification of NSCLC-derived EVs, highlighting the potential of deep learning-enhanced AFM analysis as a powerful tool for advancing liquid biopsy and precision diagnostics. Addressing sample variability and validating performance across clinical samples will be key to enabling its clinical translation.</description>
      <pubDate>Mon, 30 Jun 2025 15:00:00 GMT</pubDate>
      <guid isPermaLink="false">https://scholar.dgist.ac.kr/handle/20.500.11750/58695</guid>
      <dc:date>2025-06-30T15:00:00Z</dc:date>
    </item>
    <item>
      <title>In Silico Analysis of Binding Sites for a Novel ssDNA Aptamer Specific to Verrucarin A and Detection in Dust Extracts</title>
      <link>https://scholar.dgist.ac.kr/handle/20.500.11750/57351</link>
      <description>Title: In Silico Analysis of Binding Sites for a Novel ssDNA Aptamer Specific to Verrucarin A and Detection in Dust Extracts
Author(s): Park, Junyoung; Lee, Yoonhee; Kim, Eunjoo; Choe, Jong Kwon
Abstract: An aptamer is a single-stranded oligonucleotide that serves as a chemical antibody with a high specificity and binding affinity that can recognize a wide range of molecules. Effective modification and truncation of aptamers can enhance their binding affinities to particular targets while also broadening their application for uses, such as biosensors. However, a conventional trial-and-error methodology hinders this process. Herein, we demonstrate an in silico method to elucidate the binding site of single-stranded DNA aptamer specific to verrucarin A, a mycotoxin produced by molds in indoor buildings that causes adverse effects in living organisms. The novel ssDNA aptamer exhibited a binding affinity of 29.5 nM, demonstrating a relatively strong affinity compared to those of previously reported typical aptamers for small molecules. Furthermore, the selected aptamer was highly specific toward verrucarin A among structurally related mycotoxins (i.e., verrucarol and zearalenone). The specific binding site of the aptamer predicted via molecular dynamics and molecular docking simulations was highly consistent with the results observed via truncation, single base mutation, and circular dichroism experiments. The fluorescence assay revealed limits of detection and quantification of 4.1 and 12 nM for the aptamer, respectively. Comparing our developed aptasensor with LC-MS/MS methodology revealed that it could detect verrucarin A levels in phosphate-buffered saline and dust extracts with robust precision and consistency. Our findings provide insight for future studies exploring interaction mechanisms with intended targets and practical sensing applications, such as point-of-care detection of verrucarin A. © 2024 American Chemical Society.</description>
      <pubDate>Mon, 30 Sep 2024 15:00:00 GMT</pubDate>
      <guid isPermaLink="false">https://scholar.dgist.ac.kr/handle/20.500.11750/57351</guid>
      <dc:date>2024-09-30T15:00:00Z</dc:date>
    </item>
  </channel>
</rss>

