Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.advisor 김철기 -
dc.contributor.author Jaeyeon Choi -
dc.date.accessioned 2022-08-17T16:00:08Z -
dc.date.available 2022-08-17T16:00:08Z -
dc.date.issued 2022 -
dc.identifier.uri http://dgist.dcollection.net/common/orgView/200000628587 en_US
dc.identifier.uri http://hdl.handle.net/20.500.11750/16780 -
dc.description pulse wave, reflected wave, wave separation system, simulator -
dc.description.abstract -
dc.description.statementofresponsibility N -
dc.description.tableofcontents Ⅰ. Introduction 1
1.1 Background of the study 1
1.2 Trends of the previous study 1
1.3 Necessity of this study 4
1.4 Aim and scope of this study 5
II. Theoretical & Mathematical Development 5
2.1 Wave separation method 5
2.2 Analysis of the reflected wave characteristics 7
III. Experimental Method & Materials 8
3.1 Cardio-vascular simulator 8
3.1.1 Pulse generator part 9
3.1.2 Artificial vascular part 10
3.1.3 Distal part 12
3.1.4 Measurement part 13
3.2 Verification of the wave separation system 13
3.2.1 Comparison between PWV measurement methods 13
3.2.2 Comparison of PWV according to changes in vascular elastic modulus 14
3.3 The effect of the mother branch’s characteristics 15
3.3.1 Characteristic of the resistance 16
3.3.2 Characteristic of the compliance 17
3.4 The effect of the daughter branch’s characteristics 17
3.4.1 The comparison between the mother branch and daughter branch’s characteristics 18
3.4.2 The position of daughter branch 19
3.4.3 The number of daughter branch 20
IV. Results & Discussion 21
4.1 Verification of the wave separation system 21
4.1.1 Comparison between PWV measurement methods 21
4.1.2 Comparison of PWV according to changes in vascular elastic modulus 23
4.2 The effect of the mother branch’s characteristics 24
4.2.1 Characteristic of the resistance 24
4.2.2 Characteristic of the compliance 26
4.3 The effect of the daughter branch 28
4.3.1 Comparison with mother branch 28
4.3.2 The position of daughter branch 31
4.3.3 The number of daughter branch 33
V. Conclusion 35
VI. References 36
VII. Summary 41
-
dc.format.extent 41 -
dc.language eng -
dc.publisher DGIST -
dc.subject pulse wave, reflected wave, wave separation system, simulator -
dc.title Analysis of the Pulse wave spectrum regulated by blood vessel state -
dc.title.alternative 혈관 상태에 따른 맥파 스펙트럼 분석 -
dc.type Thesis -
dc.identifier.doi 10.22677/thesis.200000628587 -
dc.description.degree Master -
dc.contributor.department Department of Physics and Chemistry -
dc.contributor.coadvisor Sang-Hoon Shin -
dc.date.awarded 2022/08 -
dc.publisher.location Daegu -
dc.description.database dCollection -
dc.citation XT.MM 최73 202208 -
dc.date.accepted 8/11/22 -
dc.contributor.alternativeDepartment 화학물리학과 -
dc.embargo.liftdate 2027-08-31 -
dc.contributor.affiliatedAuthor Jaeyeon Choi -
dc.contributor.affiliatedAuthor ChoelGi Kim -
dc.contributor.affiliatedAuthor Sang-Hoon Shin -
dc.contributor.alternativeName 최재연 -
dc.contributor.alternativeName ChoelGi Kim -
dc.contributor.alternativeName 신상훈 -
Files in This Item:

There are no files associated with this item.

Appears in Collections:
Department of Physics and Chemistry Theses Master

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE