The use of a novel compact fluorosensor for in situ monitoring of the photocatalytic destruction of methylene blue dye effluents
Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

DC Field Value Language
dc.contributor.author Robertson, Peter K. J. -
dc.contributor.author Lee, Soo-Keun -
dc.contributor.author McStay, Daniel -
dc.contributor.author Pollard, Patricia M. -
dc.date.available 2017-07-05T08:58:53Z -
dc.date.created 2017-04-10 -
dc.date.issued 2012-06 -
dc.identifier.citation Sensors and Actuators B: Chemical, v.168, pp.118 - 122 -
dc.identifier.issn 0925-4005 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/2462 -
dc.description.abstract The use of TiO 2 photocatalysis for the destruction of dyes such as methylene blue has been extensively reported. One of the challenges faced in both the laboratory and large scale water treatment plants is the fact that the samples have to be removed from the reactor vessel and the catalyst separated prior to analysis being undertaken. In this paper we report the development of a simple fluorimeter instrument and its use in monitoring the photocatalytic destruction of methylene blue dyes in the presence of catalyst suspensions. The results reported show that the instrument provides an effective method for in situ monitoring of the photocatalytic destruction of fluorescent dyes hence allowing more accurate measurement due to the minimisation of sample loss and cross contamination. Furthermore it also provides a method for real time monitoring of the dye pollutant destruction in large scale photocatalytic reactors. © 2012 Elsevier B.V. -
dc.language English -
dc.publisher Elsevier -
dc.title The use of a novel compact fluorosensor for in situ monitoring of the photocatalytic destruction of methylene blue dye effluents -
dc.type Article -
dc.identifier.doi 10.1016/j.snb.2012.03.061 -
dc.identifier.wosid 000305379700017 -
dc.identifier.scopusid 2-s2.0-84861571335 -
dc.type.local Article(Overseas) -
dc.type.rims ART -
dc.identifier.bibliographicCitation Robertson, Peter K. J. (2012-06). The use of a novel compact fluorosensor for in situ monitoring of the photocatalytic destruction of methylene blue dye effluents. doi: 10.1016/j.snb.2012.03.061 -
dc.description.journalClass 1 -
dc.citation.publicationname Sensors and Actuators B: Chemical -
dc.contributor.nonIdAuthor Robertson, Peter K. J. -
dc.contributor.nonIdAuthor McStay, Daniel -
dc.contributor.nonIdAuthor Pollard, Patricia M. -
dc.identifier.citationVolume 168 -
dc.identifier.citationStartPage 118 -
dc.identifier.citationEndPage 122 -
dc.identifier.citationTitle Sensors and Actuators B: Chemical -
dc.type.journalArticle Article -
dc.description.isOpenAccess N -
dc.contributor.affiliatedAuthor Robertson, Peter K. J. -
dc.contributor.affiliatedAuthor Lee, Soo-Keun -
dc.contributor.affiliatedAuthor McStay, Daniel -
dc.contributor.affiliatedAuthor Pollard, Patricia M. -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

이수근
Lee, Soo-Keun이수근

Division of Energy & Environmental Technology

read more

Total Views & Downloads