Detail View
Commercial Silicon-on-Insulator (SOI) Wafers as a Versatile Substrate for Laser Desorption/Ionization Mass Spectrometry
WEB OF SCIENCE
SCOPUS
- Title
- Commercial Silicon-on-Insulator (SOI) Wafers as a Versatile Substrate for Laser Desorption/Ionization Mass Spectrometry
- DGIST Authors
- Moon, DW[Moon, Dae Won]
- Issued Date
- 2013-01
- Citation
- Kim, SH[Kim, Shin Hye]. (2013-01). Commercial Silicon-on-Insulator (SOI) Wafers as a Versatile Substrate for Laser Desorption/Ionization Mass Spectrometry. doi: 10.1007/s13361-012-0534-4
- Type
- Article
- Article Type
- Article
- Subject
- Acid Additives ; Citric Acid ; Desorption ; Detection Limits ; Electrical Equipment ; Flat Surfaces ; Heating ; Insulin ; Ions ; Laser ; Laser-Induced Surface Heating ; Laser Desorption/Ionization ; Laser Desorption/Ionization Mass Spectrometries ; Laser Desorption/Ionization Mass Spectrometry ; Laser Induced ; Lasers ; Limit of Detection ; Mass Spectrometry ; Models, Chemical ; Peptide Analysis ; Peptide Sequencing ; Peptides ; Postsource Decay ; Si Surfaces ; Silicon ; Silicon-on-Insulator (SOI) Wafer ; Silicon on Insulator Wafer ; Silicon on Insulator Wafers ; Silicon Wafers ; Soi Wafers ; Special Surfaces ; Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization ; Surface Heating ; Thermal Confinement ; Thermal Process ; Time of Flight Mass Spectrometry ; Two-Dimensional (2-D)
- ISSN
- 1044-0305
- Abstract
-
We report here that a commercial silicon-on-insulator (SOI) wafer offers an opportunity for laser desorption/ionization (LDI) of peptide molecules, which occurs directly from its flat surface without requiring special surface preparation. The LDI-on-SOI exhibits intact ionization of peptides with a good detection limit of lower than 20 fmol, of which the mass range is demonstrated up to insulin with citric acid additives. The LDI process most likely arises from laser-induced surface heating promoted by two-dimensional thermal confinement in the thin Si surface layer of the SOI wafer. As a consequence of the thermal process, the LDI-on-SOI method is also capable of creating post-source decay (PSD) of the resulting peptide LDI ions, which is suitable for peptide sequencing using conventional TOF/TOF mass spectrometry. © 2012 American Society for Mass Spectrometry.
더보기
- Publisher
- Springer
File Downloads
- There are no files associated with this item.
공유
Total Views & Downloads
???jsp.display-item.statistics.view???: , ???jsp.display-item.statistics.download???:
