Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shon, Yeong Soo | - |
dc.contributor.author | Lee, Sang-Kwon | - |
dc.contributor.author | Choi, Sie-Young | - |
dc.date.available | 2017-07-11T07:18:49Z | - |
dc.date.created | 2017-04-10 | - |
dc.date.issued | 2007-06 | - |
dc.identifier.citation | Sensor Letters, v.5, no.2, pp.421 - 424 | - |
dc.identifier.issn | 1546-198X | - |
dc.identifier.uri | http://hdl.handle.net/20.500.11750/3586 | - |
dc.description.abstract | A novel immunoassay based on a potentiometric measurement for C-reactive protein (CRP) has been developed using a BioFET and an extended gate. Both the BioFET and the extended gate were fabricated using CMOS process techniques. Id-Vd (drain voltage versus drain current) characteristics of the BioFET only and the BioFET with the extended gate were measured in PBS (phosphate buffered saline), after SAM (self-assembled monolayer) formation, after anti-CRP immobilization and after CRP antigen-antibody interaction. The relation between a current variation ratio and CRP concentration (3-10 μg/ml) was studied. Also, we observed the potential variation with increasing the area of the extended gate. The results show the feasibility of the BioFET and its integration with the extended gate for the detection of CRP In addition, it is expected that this sensing configuration could be used as a part of lab-on-a-chip for the detection of various other biomarkers. Copyright © 2007 American Scientific Publishers All rights reserved. | - |
dc.language | English | - |
dc.publisher | American Scientific Publishers | - |
dc.title | Detection of C-reactive protein using BioFET and extended gate | - |
dc.type | Article | - |
dc.identifier.doi | 10.1166/sl.2007.216 | - |
dc.identifier.wosid | 000247706300013 | - |
dc.identifier.scopusid | 2-s2.0-34547229733 | - |
dc.type.local | Article(Overseas) | - |
dc.type.rims | ART | - |
dc.description.journalClass | 1 | - |
dc.citation.publicationname | Sensor Letters | - |
dc.contributor.nonIdAuthor | Lee, Sang-Kwon | - |
dc.contributor.nonIdAuthor | Choi, Sie-Young | - |
dc.identifier.citationVolume | 5 | - |
dc.identifier.citationNumber | 2 | - |
dc.identifier.citationStartPage | 421 | - |
dc.identifier.citationEndPage | 424 | - |
dc.identifier.citationTitle | Sensor Letters | - |
dc.type.journalArticle | Article | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | BioFET | - |
dc.subject.keywordAuthor | C-reactive protein | - |
dc.subject.keywordAuthor | myocardial infarction | - |
dc.subject.keywordAuthor | extended gate | - |
dc.subject.keywordAuthor | biosensors | - |
dc.subject.keywordPlus | Antigen-Antibody Reactions | - |
dc.subject.keywordPlus | Bioassay | - |
dc.subject.keywordPlus | Biochips | - |
dc.subject.keywordPlus | BioFET | - |
dc.subject.keywordPlus | Biomarkers | - |
dc.subject.keywordPlus | BIOSENSORS | - |
dc.subject.keywordPlus | BIOSENSORS | - |
dc.subject.keywordPlus | C-Reactive Protein | - |
dc.subject.keywordPlus | CARDIOVASCULAR-DISEASE | - |
dc.subject.keywordPlus | CMOS Integrated Circuits | - |
dc.subject.keywordPlus | Extended Gate | - |
dc.subject.keywordPlus | Extended Gate | - |
dc.subject.keywordPlus | FIELD-EFFECT TRANSISTOR | - |
dc.subject.keywordPlus | Immunoassay | - |
dc.subject.keywordPlus | Immunosensors | - |
dc.subject.keywordPlus | Myocardial Infarction | - |
dc.subject.keywordPlus | Myocardial Infarction | - |
dc.subject.keywordPlus | POINT | - |
dc.subject.keywordPlus | Potentiometric Sensors | - |
dc.subject.keywordPlus | Proteins | - |
dc.contributor.affiliatedAuthor | Shon, Yeong Soo | - |
dc.contributor.affiliatedAuthor | Lee, Sang-Kwon | - |
dc.contributor.affiliatedAuthor | Choi, Sie-Young | - |
There are no files associated with this item.