Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Shon, Yeong Soo -
dc.contributor.author Lee, Sang-Kwon -
dc.contributor.author Choi, Sie-Young -
dc.date.available 2017-07-11T07:18:49Z -
dc.date.created 2017-04-10 -
dc.date.issued 2007-06 -
dc.identifier.citation Sensor Letters, v.5, no.2, pp.421 - 424 -
dc.identifier.issn 1546-198X -
dc.identifier.uri http://hdl.handle.net/20.500.11750/3586 -
dc.description.abstract A novel immunoassay based on a potentiometric measurement for C-reactive protein (CRP) has been developed using a BioFET and an extended gate. Both the BioFET and the extended gate were fabricated using CMOS process techniques. Id-Vd (drain voltage versus drain current) characteristics of the BioFET only and the BioFET with the extended gate were measured in PBS (phosphate buffered saline), after SAM (self-assembled monolayer) formation, after anti-CRP immobilization and after CRP antigen-antibody interaction. The relation between a current variation ratio and CRP concentration (3-10 μg/ml) was studied. Also, we observed the potential variation with increasing the area of the extended gate. The results show the feasibility of the BioFET and its integration with the extended gate for the detection of CRP In addition, it is expected that this sensing configuration could be used as a part of lab-on-a-chip for the detection of various other biomarkers. Copyright © 2007 American Scientific Publishers All rights reserved. -
dc.language English -
dc.publisher American Scientific Publishers -
dc.title Detection of C-reactive protein using BioFET and extended gate -
dc.type Article -
dc.identifier.doi 10.1166/sl.2007.216 -
dc.identifier.wosid 000247706300013 -
dc.identifier.scopusid 2-s2.0-34547229733 -
dc.type.local Article(Overseas) -
dc.type.rims ART -
dc.description.journalClass 1 -
dc.citation.publicationname Sensor Letters -
dc.contributor.nonIdAuthor Lee, Sang-Kwon -
dc.contributor.nonIdAuthor Choi, Sie-Young -
dc.identifier.citationVolume 5 -
dc.identifier.citationNumber 2 -
dc.identifier.citationStartPage 421 -
dc.identifier.citationEndPage 424 -
dc.identifier.citationTitle Sensor Letters -
dc.type.journalArticle Article -
dc.description.isOpenAccess N -
dc.subject.keywordAuthor BioFET -
dc.subject.keywordAuthor C-reactive protein -
dc.subject.keywordAuthor myocardial infarction -
dc.subject.keywordAuthor extended gate -
dc.subject.keywordAuthor biosensors -
dc.subject.keywordPlus Antigen-Antibody Reactions -
dc.subject.keywordPlus Bioassay -
dc.subject.keywordPlus Biochips -
dc.subject.keywordPlus BioFET -
dc.subject.keywordPlus Biomarkers -
dc.subject.keywordPlus BIOSENSORS -
dc.subject.keywordPlus BIOSENSORS -
dc.subject.keywordPlus C-Reactive Protein -
dc.subject.keywordPlus CARDIOVASCULAR-DISEASE -
dc.subject.keywordPlus CMOS Integrated Circuits -
dc.subject.keywordPlus Extended Gate -
dc.subject.keywordPlus Extended Gate -
dc.subject.keywordPlus FIELD-EFFECT TRANSISTOR -
dc.subject.keywordPlus Immunoassay -
dc.subject.keywordPlus Immunosensors -
dc.subject.keywordPlus Myocardial Infarction -
dc.subject.keywordPlus Myocardial Infarction -
dc.subject.keywordPlus POINT -
dc.subject.keywordPlus Potentiometric Sensors -
dc.subject.keywordPlus Proteins -
dc.contributor.affiliatedAuthor Shon, Yeong Soo -
dc.contributor.affiliatedAuthor Lee, Sang-Kwon -