Detail View

Highly Branched RuO2 Nanoneedles on Electrospun TiO2 Nanofibers as an Efficient Electrocatalytic Platform
Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

Title
Highly Branched RuO2 Nanoneedles on Electrospun TiO2 Nanofibers as an Efficient Electrocatalytic Platform
Issued Date
2015-07
Citation
Kim, Su-Jin. (2015-07). Highly Branched RuO2 Nanoneedles on Electrospun TiO2 Nanofibers as an Efficient Electrocatalytic Platform. ACS Applied Materials & Interfaces, 7(28), 15321–15330. doi: 10.1021/acsami.5b03178
Type
Article
Author Keywords
ruthenium oxidetitanium oxidenanoneedlenanofiberelectrocatalystH2O2 electrochemical reaction
Keywords
Analytical PerformanceCapacitorsCatalystCharge TransferCharge Transfer KineticsCrystalline MaterialsCyclic VoltammetryDetection PerformanceDiffusion-Controlled ProcessElectrocatalystElectrocatalystsElectrochemical ActivitiesElectrochemical ReactionsH2O2 Electrochemical ReactionHYDROGEN-PEROXIDE SENSORLow Detection LimitNanofiberNanofibersNanoneedleNanoneedlesNANOPARTICLESNanorodsNITRIC-OXIDEpHREDUCTIONRuthenium AlloysRuthenium CompoundsRuthenium OxideSINGLE CARBON-FIBERTitaniumTITANIUM-DIOXIDETitanium OxideTitanium Oxides
ISSN
1944-8244
Abstract
Highly single-crystalline ruthenium dioxide (RuO2) nanoneedles were successfully grown on polycrystalline electrospun titanium dioxide (TiO2) nanofibers for the first time by a combination of thermal annealing and electrospinning from RuO2 and TiO2 precursors. Single-crystalline RuO2 nanoneedles with relatively small dimensions and a high density on electrospun TiO2 nanofibers are the key feature. The general electrochemical activities of RuO2 nanoneedles-TiO2 nanofibers and Ru(OH)3-TiO2 nanofibers toward the reduction of [Fe(CN)6]3- were carefully examined by cyclic voltammetry carried out at various scan rates; the results indicated favorable charge-transfer kinetics of [Fe(CN)6]3- reduction via a diffusion-controlled process. Additionally, a test of the analytical performance of the RuO2 nanoneedles-TiO2 nanofibers for the detection of a biologically important molecule, hydrogen peroxide (H2O2), indicated a high sensitivity (390.1 ± 14.9 μA mM-1 cm-2 for H2O2 oxidation and 53.8 ± 1.07 μA mM-1 cm-2 for the reduction), a low detection limit (1 μM), and a wide linear range (1-1000 μM), indicating H2O2 detection performance better than or comparable to that of other sensing systems. © 2015 American Chemical Society.
URI
http://hdl.handle.net/20.500.11750/5181
DOI
10.1021/acsami.5b03178
Publisher
American Chemical Society
Show Full Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

손병락
Son, Byungrak손병락

Division of Energy & Environmental Technology

read more

Total Views & Downloads