Subspace-based dual quadratic discriminant analysis for motor signal classification using functional near-infrared spectroscopy

Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

DC Field Value Language
dc.contributor.author Lee, Seungjun -
dc.contributor.author Eom, Taein -
dc.contributor.author Kim, Kihwan -
dc.contributor.author Lee, Okkyun -
dc.date.accessioned 2026-08-19T09:40:12Z -
dc.date.available 2026-08-19T09:40:12Z -
dc.date.created 2026-05-22 -
dc.date.issued 2026-09 -
dc.identifier.issn 1746-8094 -
dc.identifier.uri https://scholar.dgist.ac.kr/handle/20.500.11750/60617 -
dc.description.abstract Functional near-infrared spectroscopy (fNIRS) has been used as a non-invasive modality for brain-computer interfaces (BCIs). Feature extraction is crucial for computationally efficient and performance-effective brain signal classification in fNIRS-BCI. For example, mean, peak, slope, and variance in the oxygenated hemoglobin (HbO) signal were typically used. However, there are limits to these features to exploit all the information in the measurements, and optimizing feature extraction in multi-channel signals is challenging. This paper proposes a subspace-based dual quadratic discriminant analysis (SD-QDA) to address these issues. It comprises dual quadratic and linear terms, and we optimized them for maximum discriminability within the training dataset. The difference between orthogonal projections was utilized in the quadratic terms to mitigate the small sample size problem, enabling the effective use of all multi-channel signals. We validated the method using simulation and experimental datasets (right-hand squeezing and imagining) and showed that it improved the classification accuracy compared to conventional methods. We also demonstrated that using the deoxygenated hemoglobin (HbR) signal in conjunction with HbO significantly improved the performance of the proposed method in the experimental datasets, thereby fully exploiting the fNIRS measurements in potential BCI applications. The proposed method exhibited the (maximum) accuracy for the motor signal (actual movement) at 84.5% on average and 74.7% for the motor signal imagination. -
dc.language English -
dc.publisher ELSEVIER SCI LTD -
dc.title Subspace-based dual quadratic discriminant analysis for motor signal classification using functional near-infrared spectroscopy -
dc.type Article -
dc.identifier.doi 10.1016/j.bspc.2026.110535 -
dc.identifier.wosid 001766396600001 -
dc.identifier.scopusid 2-s2.0-105038218433 -
dc.identifier.bibliographicCitation BIOMEDICAL SIGNAL PROCESSING AND CONTROL, v.123 -
dc.description.isOpenAccess FALSE -
dc.subject.keywordAuthor Brain-computer interface -
dc.subject.keywordAuthor Dual quadratic discriminant analysis -
dc.subject.keywordAuthor Functional near-infrared spectroscopy -
dc.subject.keywordAuthor Subspace-based method -
dc.subject.keywordPlus HEMODYNAMIC-RESPONSE -
dc.subject.keywordPlus FNIRS -
dc.subject.keywordPlus BCI -
dc.citation.title BIOMEDICAL SIGNAL PROCESSING AND CONTROL -
dc.citation.volume 123 -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.relation.journalResearchArea Engineering -
dc.relation.journalWebOfScienceCategory Engineering, Biomedical -
dc.type.docType Article -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

이옥균
Lee, Okkyun이옥균

Department of Robotics and Mechatronics Engineering

read more

Total Views & Downloads

???jsp.display-item.statistics.view???: , ???jsp.display-item.statistics.download???: