Communities & Collections
Researchers & Labs
Titles
DGIST
LIBRARY
DGIST R&D
Detail View
Department of New Biology
ETC
1. Journal Articles
An integrated ion-selective optode sensor cartridge for directly detecting electrolyte ions in blood plasma without pretreatment to adjust pH
Lee, Joonhyung
;
Hahn, Young Ki
;
Park, Jin-Young
;
Seo, Hyejung
;
Jung, Jaeyeon
;
Cho, Euyhyun
;
Choi, Youn-Suk
;
Lee, Soo Suk
Department of New Biology
ETC
1. Journal Articles
Citations
WEB OF SCIENCE
Citations
SCOPUS
Metadata Downloads
XML
Excel
Title
An integrated ion-selective optode sensor cartridge for directly detecting electrolyte ions in blood plasma without pretreatment to adjust pH
DGIST Authors
Lee, Joonhyung
;
Hahn, Young Ki
;
Park, Jin-Young
;
Seo, Hyejung
;
Jung, Jaeyeon
;
Cho, Euyhyun
;
Choi, Youn-Suk
;
Lee, Soo Suk
Issued Date
2019-02
Citation
Lee, Joonhyung. (2019-02). An integrated ion-selective optode sensor cartridge for directly detecting electrolyte ions in blood plasma without pretreatment to adjust pH. doi: 10.1016/j.snb.2018.10.067
Type
Article
Article Type
Article
Author Keywords
Ion-selective optode
;
Ionophore
;
Chromoionophore
;
Electrolytes
;
Cartridge
;
Absorbance
Keywords
LIPOPHILIC ANIONIC DYE
;
FILM OPTODES
;
CHLORIDE
;
POTASSIUM
;
SERUM
;
IONOPHORES
;
LIFETIME
;
URINE
;
ASSAY
ISSN
0925-4005
Abstract
We present a new integrated optode sensor cartridge that directly detects potassium, sodium, and chloride ions in blood plasma without pretreatment to adjust pH. Each optode sensor mainly consists of two separate layers, the optode and a dried buffer, which work by introducing plasma without blood cells filtered by a membrane filter. The optode layer uses a neutral ion-selective optode that is composed of an ionophore, a pH indicator dye (chromoionophore), and ionic additives incorporated in a plasticized polyvinyl chloride membrane. The dried buffer layer, which dissolves on contact with plasma, is applied to the optode layer, resulting in the constant pH of the plasma within the optode membrane. We determined the pHs of each dried buffer (potassium, sodium, and chloride) layer to be 7.0, 6.0, and 4.5, respectively, based on the pKa of their corresponding chromoionophores and effective buffer ranges. Consequently, the sensor responses varied as a function of the potassium, sodium, and chloride ion concentrations. To validate the accuracy of the ion-selective optode sensors, we investigated the correlations of potassium, sodium, and chloride ion concentrations with a commercial system (cobas® 8000) and observed comparable agreement between the two systems with correlation coefficients of 0.976, 0.955, and 0.966, respectively. © 2018 Elsevier B.V.
URI
http://hdl.handle.net/20.500.11750/9407
DOI
10.1016/j.snb.2018.10.067
Publisher
Elsevier B.V.
Show Full Item Record
File Downloads
There are no files associated with this item.
공유
공유하기
Total Views & Downloads