Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Kang, YooNa -
dc.contributor.author Chou, Namsun -
dc.contributor.author Jang, Jaewon -
dc.contributor.author Byun, Donghak -
dc.contributor.author Kang, Hosung -
dc.contributor.author Moon, Dong-Jun -
dc.contributor.author Kim, Jungsuk -
dc.contributor.author Kim, Sohee -
dc.date.accessioned 2019-07-02T09:19:41Z -
dc.date.available 2019-07-02T09:19:41Z -
dc.date.created 2019-06-12 -
dc.date.issued 2019-06 -
dc.identifier.issn 1534-4320 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/10080 -
dc.description.abstract For implantable devices, Parylene C (hereafter referred to as Parylene) has shown promising properties such as flexibility, biocompatibility, biostability, and good barrier properties. Parylene-based flexible interconnection cable (FIC) was previously developed to connect a flexible penetrating microelectrode array (FPMA) with a recording system. However, Parylene-based FIC was difficult to handle and prone to damage during the implantation surgery because of its low mechanical strength. To improve the mechanical properties of the FIC, we suggest a mechanically enhanced flexible interconnection cable (enhanced FIC) obtained using a combination of Parylene and polyimide. To investigate the long-term stability of the enhanced FIC, Parylene-only FIC, and enhanced FIC were tested and their mechanical properties were compared under an accelerated aging condition. During the course of six months of soaking, the maximum strength of the enhanced FIC remained twice as high as that of the Parylene-only FIC throughout the experiment, although the mechanical strength of both FICs decreased over time. To show the capability of the enhanced FIC in the context of nerve signal recording as a part of a neural interfacing device, it was assembled together with the FPMA and custom-made wireless recording electronics. We demonstrated the feasibility of the enhanced FIC in an in vivo application by recording acute nerve signals from canine sciatic nerves. -
dc.language English -
dc.publisher Institute of Electrical and Electronics Engineers -
dc.title An Intrafascicular Neural Interface with Enhanced Interconnection for Recording of Peripheral Nerve Signals -
dc.type Article -
dc.identifier.doi 10.1109/TNSRE.2019.2917916 -
dc.identifier.scopusid 2-s2.0-85067228800 -
dc.identifier.bibliographicCitation IEEE Transactions on Neural Systems and Rehabilitation Engineering, v.27, no.6, pp.1312 - 1319 -
dc.description.isOpenAccess FALSE -
dc.subject.keywordAuthor Intrafascicular electrode -
dc.subject.keywordAuthor neural interface -
dc.subject.keywordAuthor flexible penetrating microelectrode array (FPMA) -
dc.subject.keywordAuthor flexible interconnection cable -
dc.subject.keywordAuthor Parylene -
dc.subject.keywordPlus MULTICHANNEL ELECTRODE TIME -
dc.subject.keywordPlus NONLINEAR ENERGY OPERATOR -
dc.subject.keywordPlus SELECTIVE STIMULATION -
dc.subject.keywordPlus ARRAY -
dc.subject.keywordPlus BIOCOMPATIBILITY -
dc.subject.keywordPlus POLYIMIDE -
dc.citation.endPage 1319 -
dc.citation.number 6 -
dc.citation.startPage 1312 -
dc.citation.title IEEE Transactions on Neural Systems and Rehabilitation Engineering -
dc.citation.volume 27 -
Files in This Item:

There are no files associated with this item.

Appears in Collections:
ETC 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE