dc.description.abstract As aging population becomes a major issue in a number of countries, more medical services are increased. Wearable sensor will substitute for the role of healthcare providers to accommodate increasing requirements of rehabilitation which has characteristics of labor- intensive and time-consuming. We chose two wearable sensors such as 6 degree of freedom inertial measurement unit (6-DOF IMU) and surface electromyography (SEMG) sensor, and proposed rehabilitation applications related to early detection of disorders and home rehabilitation. First, we proposed a novel system for monitoring in-sleep stroke by detecting abnormal activity ratio of the left and right arms from wearable the 6-DOF IMU sensor which consists of an accelerometer and gyroscope sensor. We extracted multiple features for consists of an accelerometer and gyroscope sensor. We extracted multiple features for and detected stroke by sliding window method with stroke thresholds according to the each feature. The system discriminated stroke 75.48% by the accelerometer sensor and 97.12% by the gyroscope sensor in sleep data of the stroke patients with hemiparesis. Second, we tested a feasibility of the SEMG pattern recognition for training of activity daily life. We experimented from simple motions to complicated motions considering variables such as time, electrode position and person change. The results showed that the SEMG pattern recognition is largely influenced by the three variables because of structural problems in the muscle and the SEMG sensor. We concluded that the SEMG is appropriate in simple application such as co-contraction EMG detecting whether a muscle is activated. ⓒ 2014 DGIST -
dc.description.tableofcontents I. Introduction 1
--
II. Background – Current Wearable Sensor Technology 3
--
III. Stroke Detection by Accelerometer and Gyroscope 5
--
3.1 Introduction 5
--
3.2 Background 6
--
3.2.1 Stroke 6
--
3.2.2 Accelerometer 7
--
3.2.3 Gyroscope 8
--
3.2.4 Receiver Operating Characteristic (ROC) Curve 9
--
3.3 Proposed Approach for Early Detection of In-sleep Stroke 11
--
3.4 Results 16
--
3.5 Conclusion and Discussion 23
--
IV. Feasibility study of Surface EMG sensor 25
--
4.1 Introduction 25
--
4.2 Background 26
--
4.2.1 Muscle Anatomy 26
--
4.2.2 Surface EMG 28
--
4.3 Method 29
--
4.3.1 SEMG Sensor 29
--
4.3.2 Evaluation Method 30
--
4.3.3 Evaluation Items 30
--
4.3.4 Evaluation Method 31
--
4.4 Experimental Results 32
--
4.4.1 Simple Motion test 32
--
4.4.2 Complicated Motion test 33
--
4.5 Conclusion and Discussion 37
--
V. Conclusion and Future work 39
--
References 41
--
요약문 44
-
dc.format.extent 44 -
dc.language eng -
dc.publisher DGIST -
dc.subject Rehabilitation applications -
dc.subject in-sleep stroke -
dc.subject SEMG pattern recognition -
dc.subject co-contraction EMG -
dc.subject 재활 어플리케이션 -
dc.subject 수면중 뇌졸중 -
dc.subject 표면 근전도의 패턴인식 -
dc.subject 동시 수축 근전도 -
dc.title Development of Rehabilitation Applications by Using Wearable Sensors -
dc.title.alternative 착용 가능한 센서를 사용한 재활 어플리케이션 개발 -
dc.type Thesis -
dc.identifier.doi 10.22677/thesis.2262556 -
dc.description.alternativeAbstract 점차 고령화 시대로 들어감에 따라 의료서비스에 대한 요구가 늘어나고 있다. 특히 노동집약적이고 장기간 치료가 요구되는 재활분야에서는 한정된 의료계 인력을 대신해서 착용이 가능한 센서로 점차 증가되는 요구를 수용할 수 있을 것이다. 우리는 3축 엑셀로미터 센서와 3축 자이로스코프 센서를 가진 6 축 관성측정장치 센서와 표면 근전도 센서를 사용하여 질병조기진단 및 집안에서 할 수 있는 재활운동과 관련된 어플리케이션을 제안한다. 첫 번째로, 우리는 6축 관성측정장치 센서를 사용하여 팔의 좌우 비정상적인 움직임 발견함으로써 수면 중 뇌졸중을 모니터링 할 수 있는 시스템을 제안한다. 정상인과 편마비가 온 뇌졸중 환자를 구별할 수 있는 특징데이터들을 센서 데이터로부터 만들고, 각 특징데이터마다 최적의 뇌졸중 판별 기준으로 슬라이딩 윈도우 방법을 사용해서 뇌졸중을 판별해 보았다. 이 시스템을 실제 편마비가 있는 환자에게 적용하였을 때, 엑셀로미터 센서 데이터로부터는 75.48%, 자이로스코프 센서 데이터로부터는 97.12% 검출할 수 있었다. 두 번째로, 일상적인 행동의 훈련을 위한 표면 근전도 신호의 패턴인식의 가능성을 검사하였다. 우리는 시간적인 변화, 전극의 위치 변화, 사람의 변화 등 여러 변수들을 고려하여 간단한 동작부터 복잡한 동작까지 실험을 하였다. 실험결과 근전도 신호의 패턴인식은 근육과 표면 근전도 센서의 구조적인 문제로 인하여 위의 세가지 변수들에 의해서 크게 영향을 받는다. 우리는 표면근전도 센서로는 동시 수축 근전도와 같은 근육의 활성 정도만 판별하는 간단한 어플리케이션에 적합하다고 결론을 내렸다. ⓒ 2014 DGIST -
dc.description.degree Master -
dc.contributor.department Information and Communication Engineering -
dc.contributor.coadvisor Kim, Il Kon -
dc.date.awarded 2014. 2 -
dc.publisher.location Daegu -
dc.description.database dCollection -
dc.date.accepted 2016-05-18 -
dc.contributor.alternativeDepartment 대학원 정보통신융합공학전공 -
dc.contributor.affiliatedAuthor Jeon, Sang Hoon -
dc.contributor.affiliatedAuthor Son, Sang Hyuk -
dc.contributor.affiliatedAuthor Park, Tae Joon -
dc.contributor.alternativeName 전상훈 -
dc.contributor.alternativeName 손상혁 -
dc.contributor.alternativeName 박태준 -
dc.contributor.alternativeName 김일곤 -
Files in This Item:
000002262556.pdf

000002262556.pdf

기타 데이터 / 2.2 MB / Adobe PDF download
Appears in Collections:
Department of Electrical Engineering and Computer Science Theses Master

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE