Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.advisor Kim, Jong Hyun -
dc.contributor.author Hwang, Seo Yoon -
dc.date.accessioned 2017-05-10T08:54:15Z -
dc.date.available 2017-01-18T00:00:00Z -
dc.date.issued 2017 -
dc.identifier.uri http://dgist.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002324734 en_US
dc.identifier.uri http://hdl.handle.net/20.500.11750/1529 -
dc.description.abstract Muscular strength of elderly people decreased when they get older. Decreased muscular strength made decrease in quality of life of the elderly. Therefore, muscular evaluation was needed. Maximum joint moment during sit to stand could be evaluation method to maximum muscular strength to do activities of daily lives of elderly. Existed system to measure joint moments during sit to stand motion was not clinically friendly. Therefore, goal of the study was to make simplified system to measure joint moment during sit to stand motion.
To make simplified system, simplified equation which joint position and ground reaction force was used to decrease sensors to detect kinematic components. Joint position during sit to stand was estimated based on the sitting posture. Shank angle displacement during sit to stand was measured by IMU to add sitting shank angle. Thigh angle was estimated by relationship between thigh segment and edge of chair.
Joint moment for lower extremity was calculated by estimated segment angle. To see accuracy, joint moment from propsoed system was compared with joint moment from Mocap.. Most of maximum lower extremity joint moment error was less than the 20% in symmetric and asymmetric sit to stand. Also correlation coefficient was over 0.95.
For the future research, method to estimated segment angle needed to be modified to increase accuracy and validation to the elderly. ⓒ 2017 DGIST
-
dc.description.tableofcontents Ⅰ. INTRODUCTION 1--
1.1 Background 1--
1.2 Joint moment calculation during sit to stand 1--
1.3 Goal of study 3--
Ⅱ. NOMENCLATURE 5--
Ⅲ. PROPOSED SYSTEM 6--
3.1 Apparatus 6--
3.2 Joint moment equation 7--
3.3 Joint position estimation 8--
3.3.1 Sitting posture 9--
3.3.2 Sit to stand motion 9--
Ⅳ. EXPERIMENT 12--
4.1 Subject 12--
4.2 Experiment setting 12--
4.3 Experiment task 13--
4.4 Analysis method 14--
4.4.1 Data processing 14--
4.4.2 Sit to stand event detection 14--
4.4.3 Comparing joint moment 15--
Ⅴ. RESULT 17--
5.1 Pre-experiment 17--
5.2 Symmetrical sit to stand 17--
5.3 Asymmetrical sit to stand 19--
Ⅵ. DISCUSSION 22--
6.1 Comparing with conventional study 22--
6.2 Cause and method to improvement of maximum joint moment percentage error over 20% 23--
Ⅶ. CONCLUSION 27--
APPENDIX 28--
REFERENCE 40
-
dc.format.extent 43 -
dc.language eng -
dc.publisher DGIST -
dc.subject Muscular strength -
dc.subject Sit to stand -
dc.subject Maximum joint moment -
dc.subject 근력 -
dc.subject 앉았다 일어서기 -
dc.subject 최대 관절 모멘트 -
dc.title Simple calculation of joint moment for lower extremity during sit to stand motion -
dc.title.alternative 앉았다 일어서는 동작의 하지 관절 모멘트를 간단하게 계산하는 방법 -
dc.type Thesis -
dc.identifier.doi 10.22677/thesis.2324734 -
dc.description.alternativeAbstract 본 논문은 앉았다 일어서는 동작의 최대 관절 모멘트를 측정하기 위한 간단한 방법에 대하여 다룬다. 앉았다 일어서는 관절 모멘트는 일상생활에서 가장 큰 힘을 내는 동작임으로, 일상생활에서 필요한 최대 관절 모멘트를 앉았다 일어서는 동작으로 측정이 될 것이라고 기대가 된다. 이러한 관절 모멘트를 계산하기 위해서는 각 관절의 위치와 그에 작용되는 힘에 의해서 계산이 된다. 현재 가지고 있는 시스템 (모션캡쳐카메라와 포스 플레이트)을 이용하여 관절 모멘트를 계산하기에는 가격이 너무 비싸고 공간 차지가 크기 때문에 임상에서 쓰이기에는 부적절하다. 이를 해결하기 위하여, 기존연구에서는 시스템을 더 간단화하기 위한 노력이 진행중이다. 관절 모멘트를 측정하는 간단한 시스템이 만들어지게 된다면, 임상에서 환자 혹은 노인들의 앉았다 일어설 때의 관절 모멘트를 측정하여 근력 향상에 도움이 될 수 있을 것으로 예상이 된다. ⓒ 2017 DGIST -
dc.description.degree Master -
dc.contributor.department Robotics Engineering -
dc.contributor.coadvisor Lee, Yang Soo -
dc.date.awarded 2017. 2 -
dc.publisher.location Daegu -
dc.description.database dCollection -
dc.date.accepted 2017-01-18 -
dc.contributor.alternativeDepartment 대학원 로봇공학전공 -
dc.contributor.affiliatedAuthor Hwang, Seo Yoon -
dc.contributor.affiliatedAuthor Kim, Jong Hyun -
dc.contributor.affiliatedAuthor Lee, Yang Soo -
dc.contributor.alternativeName 황서윤 -
dc.contributor.alternativeName 김종현 -
dc.contributor.alternativeName 이양수 -
Files in This Item:
000002324734.pdf

000002324734.pdf

기타 데이터 / 1.78 MB / Adobe PDF download
Appears in Collections:
Department of Robotics and Mechatronics Engineering Theses Master

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE