Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Kobayashi, Yo ko
dc.contributor.author Hong, Jaesung ko
dc.contributor.author Hamano, Ryutaro ko
dc.contributor.author Okada, Kaoru ko
dc.contributor.author Fujie, Masakatsu G. ko
dc.contributor.author Hashizume, Makoto ko
dc.date.available 2017-07-11T06:56:54Z -
dc.date.created 2017-04-10 -
dc.date.issued 2012-03 -
dc.identifier.citation International Journal of Medical Robotics and Computer Assisted Surgery, v.8, no.1, pp.34 - 44 -
dc.identifier.issn 1478-5951 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/3387 -
dc.description.abstract Background: Central venous catheterization is a procedure in which a doctor inserts a catheter into a patient's vein for transfusions. Risks of this procedure include bleeding from the puncture of blood vessels and pneumothorax caused by pleural puncture. To avoid these and other risks, physicians are required to ensure that the needle is inserted securely and that it stops within the vein. Methods: We propose a robotic system for assisting venous puncture that is capable of alleviating the difficulties encountered during the conventional procedure, as well as minimizing the risks of complications. This paper describes the design and results of experiments conducted using a needle insertion manipulator. First, we investigated the relation between insertion force and angle into the vein to determine the appropriate insertion angle in relation to the blood vessel under physical conditions. The results indicated that the reaction force can be used to gauge whether the needle has been inserted into the vein in cases where the insertion angle is in the range 10-20°. Based on this result, we determined the mechanisms of the puncture device, which comprises a small, compact configuration. Experiments for accuracy validation were performed on a phantom. Results: We evaluated the positioning accuracy using ultrasound images, and the results indicated an accuracy of 1.0mm or better, which is considered feasible for venous puncture. In the phantom experiments, we confirmed that our manipulator was capable of placing the needle within the vein. Conclusions: The feasibility of this system was demonstrated in our experiments. Further studies, such as in vivo experiments, are required. © 2011 John Wiley & Sons, Ltd. -
dc.language English -
dc.publisher Wiley Blackwell -
dc.title Development of a needle insertion manipulator for central venous catheterization -
dc.type Article -
dc.identifier.doi 10.1002/rcs.420 -
dc.identifier.wosid 000301120100004 -
dc.identifier.scopusid 2-s2.0-84858007377 -
dc.type.local Article(Overseas) -
dc.type.rims ART -
dc.description.journalClass 1 -
dc.contributor.nonIdAuthor Kobayashi, Yo -
dc.contributor.nonIdAuthor Hamano, Ryutaro -
dc.contributor.nonIdAuthor Okada, Kaoru -
dc.contributor.nonIdAuthor Fujie, Masakatsu G. -
dc.contributor.nonIdAuthor Hashizume, Makoto -
dc.identifier.citationVolume 8 -
dc.identifier.citationNumber 1 -
dc.identifier.citationStartPage 34 -
dc.identifier.citationEndPage 44 -
dc.identifier.citationTitle International Journal of Medical Robotics and Computer Assisted Surgery -
dc.type.journalArticle Article -
dc.description.isOpenAccess N -
dc.contributor.affiliatedAuthor Hong, Jaesung -
Files in This Item:

There are no files associated with this item.

Appears in Collections:
Department of Robotics and Mechatronics Engineering Surgical Robotics & Augmented Reality Lab 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE