Communities & Collections
Researchers & Labs
Titles
DGIST
LIBRARY
DGIST R&D
Detail View
Department of Robotics and Mechatronics Engineering
Neural Interfaces & MicroSystems Lab
1. Journal Articles
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, Donghak
;
Cho, Sung-Joon
;
Lee, Byeong Han
;
Min, Joongkee
;
Lee, Jong-Hyun
;
Kim, Sohee
Department of Robotics and Mechatronics Engineering
Neural Interfaces & MicroSystems Lab
1. Journal Articles
Citations
WEB OF SCIENCE
Citations
SCOPUS
Metadata Downloads
XML
Excel
Title
Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Issued Date
2017-08
Citation
Byun, Donghak. (2017-08). Recording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array. Journal of Neural Engineering, 14(4), 1–14. doi: 10.1088/1741-2552/aa7493
Type
Article
Author Keywords
canine sciatic nerve
;
flexible penetrating microelectrode array (FPMA)
;
intrafascicular electrode
;
long-term implantation
;
nerve signal recording
;
neural electrode
;
neural interface
Keywords
Biocompatibility
;
Canine Sciatic Nerve
;
Cat
;
Cuff Electrode
;
Flexible Penetrating Microelectrode Array (FPMA)
;
In Vivo
;
Interface
;
Intrafascicular Electrode
;
Intrafascicular Electrodes
;
Long Term Implantation
;
Multichannel Electrode Time
;
Nerve Signal Recording
;
Neural Electrode
;
Neural Interface
;
Peripheral Nerve
;
Pudendal Nerve
;
Stimulation
ISSN
1741-2560
Abstract
Objective. Previously, we presented the fabrication and characterization of a flexible penetrating microelectrode array (FPMA) as a neural interface device. In the present study, we aim to prove the feasibility of the developed FPMA as a chronic intrafascicular recording tool for peripheral applications. Approach. For recording from the peripheral nerves of medium-sized animals, the FPMA was integrated with an interconnection cable and other parts that were designed to fit canine sciatic nerves. The uniformity of tip exposure and in vitro electrochemical properties of the electrodes were characterized. The capability of the device to acquire in vivo electrophysiological signals was evaluated by implanting the FPMA assembly in canine sciatic nerves acutely as well as chronically for 4 weeks. We also examined the histology of implanted tissues to evaluate the damage caused by the device. Main results. Throughout recording sessions, we observed successful multi-channel recordings (up to 73% of viable electrode channels) of evoked afferent and spontaneous nerve unit spikes with high signal quality (SNR > 4.9). Also, minor influences of the device implantation on the morphology of nerve tissues were found. Significance. The presented results demonstrate the viability of the developed FPMA device in the peripheral nerves of medium-sized animals, thereby bringing us a step closer to human applications. Furthermore, the obtained data provide a driving force toward a further study for device improvements to be used as a bidirectional neural interface in humans. © 2017 IOP Publishing Ltd.
URI
http://hdl.handle.net/20.500.11750/4124
DOI
10.1088/1741-2552/aa7493
Publisher
Institute of Physics Publishing
Show Full Item Record
File Downloads
There are no files associated with this item.
공유
공유하기
Related Researcher
Kim, Sohee
김소희
Department of Robotics and Mechatronics Engineering
read more
Total Views & Downloads