Communities & Collections
Researchers & Labs
Titles
DGIST
LIBRARY
DGIST R&D
Detail View
ETC
1. Journal Articles
Cerium Zirconium Oxide-Decorated Reduced Graphene Oxide Nanocomposite for Low Potential Voltammetric Detection of N-Hydroxysuccinimide
Chandran, Bhuvaneswari
;
Ramasamy, Shanmugam
;
Ponnaiah, Sathish Kumar
;
Arumugam, Elangovan
;
Chandrasekaran, Sharmila
;
Karuppaiah, Sudha
;
Ganesan, Arivazhagan
ETC
1. Journal Articles
Citations
WEB OF SCIENCE
Citations
SCOPUS
Metadata Downloads
XML
Excel
Title
Cerium Zirconium Oxide-Decorated Reduced Graphene Oxide Nanocomposite for Low Potential Voltammetric Detection of N-Hydroxysuccinimide
Issued Date
2024-03
Citation
Chandran, Bhuvaneswari. (2024-03). Cerium Zirconium Oxide-Decorated Reduced Graphene Oxide Nanocomposite for Low Potential Voltammetric Detection of N-Hydroxysuccinimide. ACS Applied Nano Materials, 7(7), 6839–6850. doi: 10.1021/acsanm.3c05485
Type
Article
Author Keywords
CZO/rGO
;
N-hydroxysuccinimide
;
electro-oxidation
;
voltammetric sensing
;
sensitivity
Keywords
NANOPARTICLES
;
ELECTRODE
;
SENSOR
;
NANOSHEETS
;
CEO2
ISSN
2574-0970
Abstract
The necessity for highly sensitive and precise methodologies for monitoring water quality and safety is imperative. The substantial health risks linked with N-hydroxysuccinimide (NHS) in water samples and its contact with the skin and eyes are noteworthy. Despite the utilization of numerous techniques for NHS analysis, the adoption of a rapid and uncomplicated electrochemical process has been infrequent. This article details the fabrication of an electrochemical NHS detection system using a cerium zirconium oxide (CZO)-doped reduced graphene oxide (rGO) nanocomposite. The CZO/rGO nanocomposite was prepared through a straightforward method involving precipitation and sonication. Structural analysis of the CZO/rGO involved various techniques, including X-ray diffraction (XRD), high-resolution transmission electron microscopy (HR-TEM), Raman spectroscopy, field emission scanning electron microscopy (FE-SEM), elemental mapping, energy dispersive X-ray analysis (EDX), and X-ray photoelectron spectroscopy analysis (XPS). Crucial kinetic parameters, such as the effective surface area, were evaluated for CZO/rGO on the glassy carbon electrode (GCE). Additionally, the CZO/rGO/GCE showcased reduced charge transfer resistance (Rct = 99 Ω), exceptional electrochemical activity, a high electron transfer rate, and strong selectivity. This electrode demonstrated excellent electrochemical sensing capabilities for NHS, boasting an extremely low detection limit (0.045 μM) and heightened sensitivity of 0.020 μA μM-1 cm-2. Demonstrating its potential for swiftly detecting NHS in river water, the CZO/rGO/GCE sensor achieved over 97% recovery. This approach is particularly well-suited for creating water pollution sensors in various sensing devices. © 2024 American Chemical Society.
URI
http://hdl.handle.net/20.500.11750/56899
DOI
10.1021/acsanm.3c05485
Publisher
American Chemical Society
Show Full Item Record
File Downloads
There are no files associated with this item.
공유
공유하기
Total Views & Downloads