Cited time in webofscience Cited time in scopus

Cerium Zirconium Oxide-Decorated Reduced Graphene Oxide Nanocomposite for Low Potential Voltammetric Detection of N-Hydroxysuccinimide

Title
Cerium Zirconium Oxide-Decorated Reduced Graphene Oxide Nanocomposite for Low Potential Voltammetric Detection of N-Hydroxysuccinimide
Author(s)
Chandran, BhuvaneswariRamasamy, ShanmugamPonnaiah, Sathish KumarArumugam, ElangovanChandrasekaran, SharmilaKaruppaiah, SudhaGanesan, Arivazhagan
Issued Date
2024-03
Citation
ACS Applied Nano Materials, v.7, no.7, pp.6839 - 6850
Type
Article
Author Keywords
CZO/rGON-hydroxysuccinimideelectro-oxidationvoltammetric sensingsensitivity
Keywords
NANOPARTICLESELECTRODESENSORNANOSHEETSCEO2
ISSN
2574-0970
Abstract
The necessity for highly sensitive and precise methodologies for monitoring water quality and safety is imperative. The substantial health risks linked with N-hydroxysuccinimide (NHS) in water samples and its contact with the skin and eyes are noteworthy. Despite the utilization of numerous techniques for NHS analysis, the adoption of a rapid and uncomplicated electrochemical process has been infrequent. This article details the fabrication of an electrochemical NHS detection system using a cerium zirconium oxide (CZO)-doped reduced graphene oxide (rGO) nanocomposite. The CZO/rGO nanocomposite was prepared through a straightforward method involving precipitation and sonication. Structural analysis of the CZO/rGO involved various techniques, including X-ray diffraction (XRD), high-resolution transmission electron microscopy (HR-TEM), Raman spectroscopy, field emission scanning electron microscopy (FE-SEM), elemental mapping, energy dispersive X-ray analysis (EDX), and X-ray photoelectron spectroscopy analysis (XPS). Crucial kinetic parameters, such as the effective surface area, were evaluated for CZO/rGO on the glassy carbon electrode (GCE). Additionally, the CZO/rGO/GCE showcased reduced charge transfer resistance (Rct = 99 Ω), exceptional electrochemical activity, a high electron transfer rate, and strong selectivity. This electrode demonstrated excellent electrochemical sensing capabilities for NHS, boasting an extremely low detection limit (0.045 μM) and heightened sensitivity of 0.020 μA μM-1 cm-2. Demonstrating its potential for swiftly detecting NHS in river water, the CZO/rGO/GCE sensor achieved over 97% recovery. This approach is particularly well-suited for creating water pollution sensors in various sensing devices. © 2024 American Chemical Society.
URI
http://hdl.handle.net/20.500.11750/56899
DOI
10.1021/acsanm.3c05485
Publisher
American Chemical Society
Files in This Item:

There are no files associated with this item.

Appears in Collections:
ETC 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE