Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Kim, Jinwoo -
dc.contributor.author Kim, Haemin -
dc.contributor.author Chang, Jin Ho -
dc.date.accessioned 2020-11-02T01:09:37Z -
dc.date.available 2020-11-02T01:09:37Z -
dc.date.created 2020-10-22 -
dc.date.issued 2020-10 -
dc.identifier.citation IEEE Access, v.8, pp.179745 - 179753 -
dc.identifier.issn 2169-3536 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/12452 -
dc.description.abstract Endoscopic photodynamic therapy (PDT) has attracted much attention as a minimally invasive, minimally toxic treatment. PDT can selectively destroy cancer cells by reactive oxygen generated through chemical reaction of photosensitizers that absorb incident light with a certain wavelength. However, the efficacy of PDT is limited due to shallow light penetration mainly caused by Rayleigh scattering in biological tissue. We previously demonstrated that the air bubbles temporarily induced by ultrasound (US) act as a Mie scattering medium, thus increasing light penetration, called US-assisted light penetration increase. For endoscopic applications of the proposed method, the endoscopic probe for US-assisted PDT should be developed; it should be as small as possible while being able to deliver laser for treatment and provide high acoustic energy for air bubble generation in the laser pathway. Satisfying those requirements is very challenging. In this paper, we report a recently developed endoscopic probe for US-assisted PDT that meets the requirements. The probe consists of two 3 MHz US transducers placed side by side and tilted at an angle of 25◦ and an optical fiber for laser delivery. The probe size was measured at 60.5 mm × 14 mm × 14 mm suitable for endoscopic applications. In the experiment, it was shown that the probe could increase the laser intensity by 28%, compared to the laser only illumination. Even this increase is higher than the previous measurement using a commercial ring-shaped 1.1 MHz HIFU transducer with outer and inner diameters of 64 mm and 22.6 mm. © 1991 BMJ Publishing Group. All rights reserved. -
dc.language English -
dc.publisher Institute of Electrical and Electronics Engineers Inc. -
dc.title Endoscopic Probe for Ultrasound-Assisted Photodynamic Therapy of Deep-Lying Tissue -
dc.type Article -
dc.identifier.doi 10.1109/ACCESS.2020.3026372 -
dc.identifier.wosid 000577941800001 -
dc.identifier.scopusid 2-s2.0-85100319942 -
dc.type.local Article(Overseas) -
dc.type.rims ART -
dc.description.journalClass 1 -
dc.citation.publicationname IEEE Access -
dc.contributor.nonIdAuthor Kim, Jinwoo -
dc.contributor.nonIdAuthor Kim, Haemin -
dc.identifier.citationVolume 8 -
dc.identifier.citationStartPage 179745 -
dc.identifier.citationEndPage 179753 -
dc.identifier.citationTitle IEEE Access -
dc.type.journalArticle Article -
dc.description.isOpenAccess Y -
dc.subject.keywordAuthor Ultrasonic transducers -
dc.subject.keywordAuthor biomedical transducers -
dc.subject.keywordAuthor biophotonics -
dc.subject.keywordAuthor light scattering -
dc.subject.keywordAuthor photodynamic therapy -
dc.subject.keywordAuthor ultrasound-induced microbubbles -
dc.subject.keywordPlus CANCER -
dc.subject.keywordPlus TRANSDUCER -
dc.subject.keywordPlus PRESSURE -
dc.subject.keywordPlus FUTURE -
dc.contributor.affiliatedAuthor Kim, Jinwoo -
dc.contributor.affiliatedAuthor Kim, Haemin -
dc.contributor.affiliatedAuthor Chang, Jin Ho -

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE