Detail View

Measurement of pulse transit time using ultra-wideband radar
Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

DC Field Value Language
dc.contributor.author Cho, Hui-Sup -
dc.contributor.author Park, Young-Jin -
dc.date.accessioned 2021-01-22T07:24:09Z -
dc.date.available 2021-01-22T07:24:09Z -
dc.date.created 2020-11-16 -
dc.date.issued 2021-09 -
dc.identifier.citation Technology and Health Care, v.29, no.5, pp.859 - 868 -
dc.identifier.issn 0928-7329 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/12752 -
dc.description.abstract BACKGROUND: The pulse transit time is an important factor that can be used to estimate the blood pressure indirectly. In many studies, pressures in the artery near and far from the heart are measured or the electrocardiogram and photoplethysmography are used to calculate the pulse transit time. In other words, the so-called contact measurements have been mainly used in these studies. OBJECTIVE: In this paper, a new method based on radar technology to measure the pulse transit time in a non-contact manner is proposed. METHODS: Radar pulses were simultaneously emitted to the chest and the wrist, and the reflected pulses were accumulated. Heartbeats were extracted by performing principal component analysis on each time series belonging to the accumulated pulses. Then, the matched heartbeat pairs were found among the heartbeats obtained from the chest and wrist and the time delay between them, i.e. the pulse transit time, was obtained. RESULTS: By comparing the pulse transit times obtained by the proposed method with those obtained by conventional methods, it is confirmed that the proposed method using the radar can be used to obtain the pulse transit time in a non-contact manner. © 2021 -IOS Press and the authors. All rights reserved. -
dc.language English -
dc.publisher IOS Press -
dc.title Measurement of pulse transit time using ultra-wideband radar -
dc.type Article -
dc.identifier.doi 10.3233/THC-202626 -
dc.identifier.wosid 000697390600002 -
dc.identifier.scopusid 2-s2.0-85115654688 -
dc.type.local Article(Overseas) -
dc.type.rims ART -
dc.identifier.bibliographicCitation Cho, Hui-Sup. (2021-09). Measurement of pulse transit time using ultra-wideband radar. doi: 10.3233/THC-202626 -
dc.description.journalClass 1 -
dc.citation.publicationname Technology and Health Care -
dc.identifier.citationVolume 29 -
dc.identifier.citationNumber 5 -
dc.identifier.citationStartPage 859 -
dc.identifier.citationEndPage 868 -
dc.identifier.citationTitle Technology and Health Care -
dc.description.isOpenAccess Y -
dc.subject.keywordAuthor Ultra-wide band -
dc.subject.keywordAuthor impulse radar -
dc.subject.keywordAuthor pulse transit time -
dc.subject.keywordAuthor principal component analysis -
dc.subject.keywordAuthor heartbeat -
dc.contributor.affiliatedAuthor Cho, Hui-Sup -
dc.contributor.affiliatedAuthor Park, Young-Jin -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

조희섭
Cho, Hui-Sup조희섭

Division of AI, Big data and Block chain

read more

Total Views & Downloads