Cited time in webofscience Cited time in scopus

Fluorescent paper strip immunoassay with carbon nanodots@silica for determination of human serum amyloid A1

Title
Fluorescent paper strip immunoassay with carbon nanodots@silica for determination of human serum amyloid A1
Author(s)
Supianto, MulyaLee, Sang HyukJhung, Sung HwaMohammad Hazara BegumMinh Hung VuKim, Min-SikSong, Woo-YoungKim, Tae-YoungLee, Hye Jin
Issued Date
2021-11
Citation
Microchimica Acta, v.188, no.11
Type
Article
Author Keywords
Carbon nanodots@silicaFluorescent paper stripHuman serum amyloid A1Lung cancerSerum analysis
Keywords
LUNG-CANCERPROTEIN CORONAQUANTIFICATIONVALIDATION
ISSN
0026-3672
Abstract
A fluorescent paper strip immunoassay in conjunction with carbon nanodots@silica (CND@SiO2) as a label was developed for the quantitative measurements of human serum amyloid A1 (hSAA1) in serum at clinically significant concentrations for lung cancer diagnosis. Monodispersed CND@SiO2 was prepared by cohydrolysis between silane-crosslinked carbon nanodots and silica precursors via the Ströber method and further attached covalently to anti-hSAA1 (14F8) monoclonal antibody [anti-hSAA1(14F8)] specific to the hSAA1 target. The hSAA1 concentrations were then determined by quantifying the blue fluorescence intensity upon 365nm excitation of the captured hSAA1 with anti-hSAA1(14F8)-CND@SiO2 conjugates in the test line on a paper strip where anti-hSAA1 (10G1) monoclonal antibody was physisorbed. The developed fluorescent paper strip with CND@SiO2 can detect hSAA1 at concentrations ranging from 0.1 to 5nM (R2 = 0.995), with a limit of detection of 0.258nM in 10mM phosphate buffer pH 7.4 containing human serum albumin. Theperformance of recovery (90.98–109.17%) and repeatability (coefficients of variation < 8.46%) obtained was also acceptable for quantitative determinations. Theplatform was employed for direct determinationof hSAA1 concentrations in undiluted serum samples from lung cancer patients (relative standard deviation (RSD) < 7.46%) and healthyhumans (RSD < 3.96%). The results were compared with those obtained using a commercially available enzyme-linked immunosorbent assay alongside liquid chromatography with tandem mass spectrometry measurements. Graphical abstract: [Figure not available: see fulltext.]. © 2021, The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature.
URI
http://hdl.handle.net/20.500.11750/15794
DOI
10.1007/s00604-021-05019-1
Publisher
Springer Verlag
Related Researcher
  • 김민식 Kim, Min-Sik
  • Research Interests Cancer Proteogenomics; Biomarker Discovery; Integrative Multi-Omics
Files in This Item:

There are no files associated with this item.

Appears in Collections:
Department of New Biology Laboratory for QBIO and Precision Medicine 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE