Cited time in webofscience Cited time in scopus

A Novel Machine Learning Approach to Classify and Detect Atrial Fibrillation Using Optimized Implantable Electrocardiogram Sensor

Title
A Novel Machine Learning Approach to Classify and Detect Atrial Fibrillation Using Optimized Implantable Electrocardiogram Sensor
Author(s)
Yazdi, Seyed Jamaleddin MostafaviPark, Hee-JoonSon, Chang-SikLee, Jong-Ha
DGIST Authors
Yazdi, Seyed Jamaleddin MostafaviPark, Hee-JoonSon, Chang-SikLee, Jong-Ha
Issued Date
2021-10
Type
Article
Author Keywords
Atrial Fibrillation (AFib)Difference operation method (DOM)Global covering rule discoveryImplantable ECG coilOptimizationPower transfer efficiency (PTE)
Keywords
PRINTED SPIRAL COILSNEURAL-NETWORKIN-VIVOCLASSIFICATIONDIAGNOSISRECONSTRUCTIONSYSTEMDECOMPOSITIONREDUCTIONDESIGN
ISSN
2169-3536
Abstract
There are some constraints such as external electrodes, a failure to capture most paroxysmal atrial fibrillation (AFib), low power transfer efficiency (PTE) for 24/7 charging technology, a short period of monitoring, and automatic detection of AFib in conventional electrocardiogram (ECG) sensors. To overcome these constraints, an implantable ECG sensor with a 2-coil inductive link with maximum power transfer efficiency (PTE) is designed to continuously monitor patients and efficiently detect AFib using global covering rule discovery and the minimum description length (MDL) algorithm. Among different combinations of ECG coils, the square spiral-square spiral coil demonstrates the maximum PTE, 56.23the resonant frequency of 13.56 MHz and it is used in the implantable ECG sensor. The QRS complex from ECG signals of twenty-nine AFib patients is detected using different operation methods (DOM). The MDL algorithm is used to group 12 features of heart rate variability (HRV) parameters. The global covering rule discovery is proposed as a novel classification technique of AFib in ECG data. The average classification accuracy was 96.67 ± 7.03, and then the average recall, precision, F1-measures, and an average number of generated rules were 97.08 ± 6.23, 97.08 ± 6.23, 96.57 ± 7.23, and 7.9 ± 0.32, respectively. We found that the NN50, pNN50, and LF parameters can distinguish the AFib patient better than a healthy one. Among these parameters, pNN50 showed that it is greater than 34.75 in 41.38% of patients. The optimized implantable ECG sensor with a maximum PTE of 56.23% along with novel AFib detection and classification methods is suitable for its implementation in future implantable ECG sensors. Author
URI
http://hdl.handle.net/20.500.11750/15894
DOI
10.1109/access.2021.3123367
Publisher
Institute of Electrical and Electronics Engineers Inc.
Files in This Item:

There are no files associated with this item.

Appears in Collections:
ETC 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE