Communities & Collections
Researchers & Labs
Titles
DGIST
LIBRARY
DGIST R&D
Detail View
Department of Robotics and Mechatronics Engineering
Multiscale Biomedical Robotics Laboratory
1. Journal Articles
Reprogrammable Magnetically Actuated Self-Assembled Cilia Array
Sohn, Sunwoo
;
Lee, Hyoryong
;
Kee, Hyeonwoo
;
Park, Sukho
Department of Robotics and Mechatronics Engineering
Multiscale Biomedical Robotics Laboratory
1. Journal Articles
Citations
WEB OF SCIENCE
Citations
SCOPUS
Metadata Downloads
XML
Excel
Title
Reprogrammable Magnetically Actuated Self-Assembled Cilia Array
Issued Date
2023-01
Citation
Sohn, Sunwoo. (2023-01). Reprogrammable Magnetically Actuated Self-Assembled Cilia Array. Advanced Intelligent Systems, 5(1). doi: 10.1002/aisy.202200227
Type
Article
Author Keywords
biomimetics
;
fluidic channel
;
magnetic actuators
;
metachronal wave
;
reprogrammable artificial cilia
Keywords
ARTIFICIAL CILIA
;
MOTILE CILIA
;
PROPULSION
ISSN
2640-4567
Abstract
Motile cilia move in an asymmetric pattern and implement a metachronal wave (MCW) to facilitate fluid movement in a viscous environment. Studies have been conducted to mimic MCW movement of motile cilia, but the fabrication process is too complicating or there are difficulties in accurately mimicking the shape of the cilia. To overcome these limitations, a self-assembly method is introduced to fabricate a reprogrammable magnetically actuated self-assembled (RMS) cilia array that can be reprogrammed by changing the magnetization direction through additional magnetization. Using the RMS cilia array, a unilateral cilia array (UCA) channel and a bilateral cilia array (BCA) channel are constructed, and the motion and fluid flow of the RMS cilia array are analyzed by applying different magnetic fields (strike magnetic field and rotating magnetic field). When a rotating magnetic field is applied to the UCA channel, a distinct MCW appears. In the BCA channel test, fluid pumping is observed when a strike magnetic field is applied, whereas fluid mixing is observed when a rotating magnetic field is applied. Based on these results, it is expected that the proposed RMS cilia array and magnetic field actuation can be applied to lab-on-a-chip or microfluidic channels for fluid mixing and pumping. © 2022 The Authors. Advanced Intelligent Systems published by Wiley-VCH GmbH
URI
http://hdl.handle.net/20.500.11750/17192
DOI
10.1002/aisy.202200227
Publisher
Wiley
Show Full Item Record
File Downloads
There are no files associated with this item.
공유
공유하기
Related Researcher
Park, Sukho
박석호
Department of Robotics and Mechatronics Engineering
read more
Total Views & Downloads