Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Jung, Eui Sung ko
dc.contributor.author Shin, Dong Ho ko
dc.contributor.author Seong, Ki Woong ko
dc.contributor.author Lee, Jyung Hyung ko
dc.contributor.author Lee, Jang Woo ko
dc.contributor.author Cho, Hui Sup ko
dc.contributor.author Kim, Myoung Nam ko
dc.contributor.author Cho, Jin Ho ko
dc.date.available 2017-07-11T07:57:15Z -
dc.date.created 2017-06-28 -
dc.date.issued 2012 -
dc.identifier.citation IEEE-EMBS International Conference on Biomedical and Health Informatics, BHI 2012. In Conj. with the 8th Int. Symp.on Medical Devices and Biosensors and the 7th Int. Symp. on Biomedical and Health Engineering, pp.297 - 300 -
dc.identifier.isbn 9780000000000 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/3850 -
dc.description.abstract A microphone implanted under the skin became a significant issue owing to the advent of fully-implantable hearing aids (F-IHAs). And, the design of implantable microphone is needed to be considered the biocompatibility, effects of the human skin and directivity. However, there were few studies to develop implantable microphone to consider directivity. In this paper, to design and implement the implantable microphone for the F-IHA, the directivity of the implantable microphone placed under an artificial skin model was measured. The artificial skin used the test model was made by a gelatin gel that was normally studied as soft tissue model of an ultra-sound phantom. And acoustic properties of the test model skin are similar to it of rats that are the transmission loss and the absorption coefficient. © 2012 IEEE. -
dc.publisher Institute of Electrical and Electronics Engineers Inc. -
dc.title Measurement of directivity for the design of an implantable microphone implanted under an artificial skin model -
dc.type Conference -
dc.identifier.doi 10.1109/BHI.2012.6211571 -
dc.identifier.scopusid 2-s2.0-84864219309 -
dc.type.rims CONF -
dc.contributor.nonIdAuthor Jung, Eui Sung -
dc.contributor.nonIdAuthor Shin, Dong Ho -
dc.contributor.nonIdAuthor Seong, Ki Woong -
dc.contributor.nonIdAuthor Lee, Jyung Hyung -
dc.contributor.nonIdAuthor Lee, Jang Woo -
dc.contributor.nonIdAuthor Kim, Myoung Nam -
dc.contributor.nonIdAuthor Cho, Jin Ho -
dc.identifier.citationStartPage 297 -
dc.identifier.citationEndPage 300 -
dc.identifier.citationTitle IEEE-EMBS International Conference on Biomedical and Health Informatics, BHI 2012. In Conj. with the 8th Int. Symp.on Medical Devices and Biosensors and the 7th Int. Symp. on Biomedical and Health Engineering -
dc.type.journalArticle Conference Proceedings -
dc.identifier.conferencecountry US -
dc.identifier.conferencelocation Hong Kong and Shenzhen -
dc.contributor.affiliatedAuthor Cho, Hui Sup -
Files in This Item:

There are no files associated with this item.

Appears in Collections:
Intelligent Devices and Systems Research Group 2. Conference Papers

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE