All-in-one low-intensity pulsed ultrasound stimulation system using piezoelectric micromachined ultrasonic transducer (pMUT) arrays for targeted cell stimulation
Lee, Won-Jun
;
Yoo, Seung-Jun
;
Jung, Joon-Taek
;
Kang, Woo-Jin
;
Wang, Wei
;
Moon, Cheil
;
Choi, Hong-Soo
Department of Brain Sciences
Laboratory of Chemical Senses
1. Journal Articles
Department of Robotics and Mechatronics Engineering
Bio-Micro Robotics Lab
1. Journal Articles
Citations
WEB OF SCIENCE
Citations
SCOPUS
Metadata Downloads
XML
Excel
Title
All-in-one low-intensity pulsed ultrasound stimulation system using piezoelectric micromachined ultrasonic transducer (pMUT) arrays for targeted cell stimulation
Issued Date
2017-12
Citation
Lee, Won-Jun. (2017-12). All-in-one low-intensity pulsed ultrasound stimulation system using piezoelectric micromachined ultrasonic transducer (pMUT) arrays for targeted cell stimulation. Biomedical Microdevices, 19(4). doi: 10.1007/s10544-017-0228-6
Type
Article
Author Keywords
Ultrasonic transducer
;
Cell stimulation system
;
pMUT
;
Proliferation
Keywords
Brain-Function
;
Cell Stimulation System
;
Chondrocytes
;
Culture Temperature
;
Differentiation
;
Electrical-Stimulation
;
Low-Frequency
;
Nerve Growth-Factor
;
PC12 Cells
;
pMUT
;
Proliferation
;
Rat
;
Transcranial Magnetic Stimulation
;
Ultrasonic Transducer
;
Ultrasound
ISSN
1387-2176
Abstract
A novel cell-stimulation system was fabricated using 10 × 29 piezoelectric micromachined ultrasonic transducer (pMUT) arrays for targeted ultrasonic cell stimulation. Both the diameter of a single pMUT element and the edge-to-edge gap were 120 μm, and the size of a pMUT array was 2.27 × 6.84 mm, to be placed at the bottom of a Transwell. The measured resonance frequency of a single pMUT element was 1.48 ± 0.13 MHz and the measured acoustic intensity of the pMUT array was 0.15 ± 0.03 MPa at 1 mm away from the transducer. A pMUT array was mounted on a print circuit board (PCB), which was designed in accordance with the size of a 12-well Transwell. The Transwell was placed on the PCB and wire bonding was performed to electrically connect the PCB and pMUT arrays. After wiring, the PCB and pMUT arrays were coated with 2.6-μm thick parylene-C to ensure biocompatibility and waterproofing. PC12 cells were used for ultrasonic cell stimulation tests to examine the proposed all-in-one low-intensity pulsed ultrasound stimulation system. Various stimulation times and duty cycles were used simultaneously for cell proliferation in a confined cell culture environment. All stimulation groups showed increased cell proliferation rates, in the range 138–166%, versus the proliferation rate of the control group. © 2017, Springer Science+Business Media, LLC.
URI
http://hdl.handle.net/20.500.11750/4582
DOI
10.1007/s10544-017-0228-6
Publisher
Springer New York LLC
Show Full Item Record
File Downloads
There are no files associated with this item.
공유
공유하기
Related Researcher
Moon, Cheil
문제일
Department of Brain Sciences
read more
Total Views & Downloads