Communities & Collections
Researchers & Labs
Titles
DGIST
LIBRARY
DGIST R&D
Detail View
Department of Robotics and Mechatronics Engineering
Multiscale Biomedical Robotics Laboratory
1. Journal Articles
Eco-friendly phyllanthus emblica-based ionic polymer composite for enhanced mechanical, electrical, and wearable sensing performance
Mohanty, Sribidhya
;
Panwar, Varij
;
Anoop, Gopinathan
;
Park, Sukho
Department of Robotics and Mechatronics Engineering
Multiscale Biomedical Robotics Laboratory
1. Journal Articles
Citations
WEB OF SCIENCE
Citations
SCOPUS
Metadata Downloads
XML
Excel
Title
Eco-friendly phyllanthus emblica-based ionic polymer composite for enhanced mechanical, electrical, and wearable sensing performance
Issued Date
2023-07
Citation
Mohanty, Sribidhya. (2023-07). Eco-friendly phyllanthus emblica-based ionic polymer composite for enhanced mechanical, electrical, and wearable sensing performance. Materials Chemistry and Physics, 303. doi: 10.1016/j.matchemphys.2023.127791
Type
Article
Author Keywords
Ionic polymer
;
Composite
;
Eco-friendly
;
Phyllanthus emblica
;
Wearable sensor
Keywords
SENSOR
;
NANOCOMPOSITES
;
ELECTROLYTE
;
MORPHOLOGY
;
MEMBRANES
;
LIQUID
ISSN
0254-0584
Abstract
In this intelligent society, wearable technology is in high demand. Long-term contact between these wearable gadgets and the human body creates a demand for the eco-friendly flexible sensors. Here, for the first time, an ionic polymer composite (IPC) based on eco-friendly phyllanthus emblica (PE, Indian gooseberry) liquid extract and polyvinyl alcohol (PVA) is proposed for wearable sensing applications. Because of the ionic conducting elements such as sulphur (S), oxygen (O), iron (Fe), magnesium (Mg), and the presence of fibers in the PE, the PVA/PE IPC with a blending ratio of 1/11 generated 1.5 x 105, 18, and 1.86 folds of higher dielectric constant, ionic conductivity and higher tensile strain than that of the PVA sample. The PVA/PE IPC membranes could not dissolve in water for a month and maintain elasticity. The 1/11 IPC sensor also exhibited 28 folds higher sensitivity (Delta R/R = 0.45) and gauge factor (G = 51) than that of the PVA sample and was beneficial for pie-zoresistive applications. When the IPC sensor was placed on the human neck and fingers, signals were detected from breathing and finger-bending-induced strain, making it feasible for wearable devices. The motion test of IPC showed proper variation in sensing resistance when IPC encountered a motion, which is highly suitable for wearable devices. The proposed IPC is an eco-friendly option for piezoresistive applications such as wearable sensors and eco-friendly ionic skins. © 2023 Elsevier B.V.
URI
http://hdl.handle.net/20.500.11750/46666
DOI
10.1016/j.matchemphys.2023.127791
Publisher
Elsevier BV
Show Full Item Record
File Downloads
There are no files associated with this item.
공유
공유하기
Related Researcher
Park, Sukho
박석호
Department of Robotics and Mechatronics Engineering
read more
Total Views & Downloads