Lissajous confocal fluorescent endomicroscopy with a lever mechanism and a frequency separation by an asymmetric polymer tube
Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

DC Field Value Language
dc.contributor.author Im, Jintaek -
dc.contributor.author Chang, Yeonhee -
dc.contributor.author Lee, Myung Ho -
dc.contributor.author Do, Dukho -
dc.contributor.author Lee, Kyuhang -
dc.contributor.author Gweon, Daegab -
dc.contributor.author Song, Cheol -
dc.date.accessioned 2024-01-03T09:40:12Z -
dc.date.available 2024-01-03T09:40:12Z -
dc.date.created 2023-08-17 -
dc.date.issued 2023-12 -
dc.identifier.issn 1559-9612 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/47527 -
dc.description.abstract We present a confocal fluorescent endomicroscopic system with a Lissajous scan using an asymmetric polymer tube and piezoelectric (PZT) tube actuator. The fiber cantilever’s scanning part is often inside the PZT tube actuator to reduce the scanner’s rigid length and enhance the beam deflection via a lever mechanism. Here, the mathematical model of the PZT tube actuator-based lever mechanism is first proposed by considering the piezoelectric parameters of the actuator and Euler-Bernoulli beam deflection, showing a good agreement with experimental data. In addition, an elliptical polymer tube is used to divide the resonant frequencies of the fiber cantilever, allowing enough scanning amplitudes and alleviating the inherent cross-coupling issue of a PZT tube actuator. The design optimization is performed by selecting the optimal lever length and the shape of the PFA tube. The implemented endomicroscopic probe could successfully acquire imaging results from both a lens-cleaning tissue and an ex-vivo mouse colon. © 2023 The Author(s). Published with license by Taylor & Francis Group, LLC. -
dc.language English -
dc.publisher Taylor and Francis -
dc.title Lissajous confocal fluorescent endomicroscopy with a lever mechanism and a frequency separation by an asymmetric polymer tube -
dc.type Article -
dc.identifier.doi 10.1080/15599612.2023.2238009 -
dc.identifier.wosid 001036271600001 -
dc.identifier.scopusid 2-s2.0-85165748345 -
dc.identifier.bibliographicCitation Im, Jintaek. (2023-12). Lissajous confocal fluorescent endomicroscopy with a lever mechanism and a frequency separation by an asymmetric polymer tube. International Journal of Optomechatronics, 17(1). doi: 10.1080/15599612.2023.2238009 -
dc.description.isOpenAccess TRUE -
dc.subject.keywordAuthor confocal endomicroscopy -
dc.subject.keywordAuthor fiber cantilever -
dc.subject.keywordAuthor lever mechanism -
dc.subject.keywordAuthor Lissajous scanning -
dc.subject.keywordPlus HIGH-SPEED -
dc.subject.keywordPlus FIBER -
dc.subject.keywordPlus ENDOSCOPE -
dc.subject.keywordPlus SCANNER -
dc.citation.number 1 -
dc.citation.title International Journal of Optomechatronics -
dc.citation.volume 17 -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.relation.journalResearchArea Engineering; Optics -
dc.relation.journalWebOfScienceCategory Engineering, Electrical & Electronic; Engineering, Mechanical; Optics -
dc.type.docType Article -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

송철
Song, Cheol송철

Department of Robotics and Mechatronics Engineering

read more

Total Views & Downloads