Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Joe, Seong Gun ko
dc.contributor.author Lee, Dong Kyu ko
dc.contributor.author Park, Jong Oh ko
dc.contributor.author Park, Suk Ho ko
dc.contributor.author Kim, Byung Gyu ko
dc.date.available 2018-02-05T04:12:50Z -
dc.date.created 2018-01-17 -
dc.date.issued 2017-03 -
dc.identifier.citation International Journal Of Precision Engineering And Manufacturing, v.18, no.3, pp.461 - 465 -
dc.identifier.issn 2234-7593 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/5656 -
dc.description.abstract Most robotic colonoscopes do not allow sufficient space for high capacity motors since their power sources are equipped in their bodies. Therefore, a robotic colonoscope activated by an external motor through a flexible shaft has been presented. Unfortunately, robot rotations resulting from excessive input torque are observed under some input voltage signals. These rotations occur when the load torque on the flexible shaft exceeds a critical torque value, which is the maximum torque satisfying the rigid body condition. The excessive-torque effect must be eliminated since each rotation causes a velocity reduction as well as twisting of the colon. Therefore, to suppress the rotation by reducing the load torque, the input and load torques are investigated in connection to the input signal. Conclusively, the maximum load torque of the triangular function is the smallest among the input signals and does not exceed the critical torque, which causes the rotation of the robot body. To verify the usefulness of the theoretical and experimental load torque results, in-vitro tests are performed in an acrylic pipe and excised colon for all input functions. As expected with the load torque results according to the input signal, the robot with the triangular function achieves the best performance regardless of experimental environment. © 2017, Korean Society for Precision Engineering and Springer-Verlag Berlin Heidelberg. -
dc.language English -
dc.publisher KOREAN SOC PRECISION ENG -
dc.subject TRACT -
dc.title Input Signal Effects on the Locomotion of a Robotic Colonoscope Activated by a Flexible Shaft -
dc.type Article -
dc.identifier.doi 10.1007/s12541-017-0055-y -
dc.identifier.wosid 000396238700021 -
dc.identifier.scopusid 2-s2.0-85014916903 -
dc.type.local Article(Overseas) -
dc.type.rims ART -
dc.description.journalClass 1 -
dc.contributor.nonIdAuthor Joe, Seong Gun -
dc.contributor.nonIdAuthor Lee, Dong Kyu -
dc.contributor.nonIdAuthor Park, Jong Oh -
dc.contributor.nonIdAuthor Kim, Byung Gyu -
dc.identifier.citationVolume 18 -
dc.identifier.citationNumber 3 -
dc.identifier.citationStartPage 461 -
dc.identifier.citationEndPage 465 -
dc.identifier.citationTitle International Journal Of Precision Engineering And Manufacturing -
dc.type.journalArticle Article -
dc.description.isOpenAccess N -
dc.contributor.affiliatedAuthor Park, Suk Ho -
Files in This Item:

There are no files associated with this item.

Appears in Collections:
Department of Robotics and Mechatronics Engineering Multiscale Biomedical Robotics Laboratory 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE