Detail View
A Hybrid Recording System with 10kHz-BW 630mVPP84.6dB-SNDR 173.3dB-FOMSNDRand 5kHz-BW 114dB-DR for Simultaneous ExG and Biocurrent Acquisition
- Department of Electrical Engineering and Computer Science
- Advanced Electronic Devices Research Group(AEDRG) - Kang Lab.
- 2. Conference Papers
- Department of Electrical Engineering and Computer Science
- Integrated Nano-Systems Laboratory
- 2. Conference Papers
- Department of Electrical Engineering and Computer Science
- Advanced Electronic Devices Research Group(AEDRG) - Jang Lab.
- 2. Conference Papers
WEB OF SCIENCE
SCOPUS
- Title
- A Hybrid Recording System with 10kHz-BW 630mVPP84.6dB-SNDR 173.3dB-FOMSNDRand 5kHz-BW 114dB-DR for Simultaneous ExG and Biocurrent Acquisition
- Issued Date
- 2024-02-21
- Citation
- Seol, Taeryoung. (2024-02-21). A Hybrid Recording System with 10kHz-BW 630mVPP84.6dB-SNDR 173.3dB-FOMSNDRand 5kHz-BW 114dB-DR for Simultaneous ExG and Biocurrent Acquisition. International Solid-State Circuits Conference, 562–564. doi: 10.1109/ISSCC49657.2024.10454270
- Type
- Conference Paper
- ISBN
- 9798350306200
- ISSN
- 0193-6530
- Abstract
-
As the precise acquisition of continuous ExG (ENG, ECG, etc.) and biocurrent (chemical, PPG, etc.) signals provides further insights into chronic health conditions [1,2], a lowpower readout system capable of simultaneously recording ExG and biocurrent signals with high precision is beneficial (Fig. 33.11.1(a)). Such a system requires BW>5kHz, noise floor ~100nV/√Hz, and FOMSNDR>170dB to cover the entire ExG spectrum. Also, an input range (IR)>100mVPP is necessary to prevent saturation. Likewise, for biocurrent acquisition, a system has to meet BW>1kHz, noise floor ~1pArms/√Hz, and DR>100dB to detect small charge perturbations without saturation from large baseline currents. Extensive effort has been conducted to design a simultaneous V & I monitoring system (Fig. 33.11.1(b)). For instance, [1] allows the design of a simultaneous V & I monitoring system based on simple integration of individual readout schemes. However, this system consumes power >100μW and is unsuitable for simultaneous ExG and biocurrent signals due to the limited BW. Although [2] achieves wide BW for both signals, it cannot record V & I simultaneously due to the time-division manner and also has narrow IRs. On the other hand, [3] employing frequency division, achieves simultaneous readout while consuming low power. However, it is vulnerable to artifacts, while the BW of each V & I readout limits the other. This paper presents a simultaneous V & I recording system using a single 2nd-order continuous-time ΔΣ modulator (CT-DSM). Such simultaneous recording is achieved by using a highly linear hybrid GmC integrator with a triplet VCObased quantizer, where the differential voltage and single-ended current are combined into differential and common mode signals (Fig. 33.11.1 (c)). © 2024 IEEE.
더보기
- Publisher
- IEEE Solid-State Circuits Society
File Downloads
- There are no files associated with this item.
공유
Related Researcher
- Jang, Jae Eun장재은
-
Department of Electrical Engineering and Computer Science
Total Views & Downloads
???jsp.display-item.statistics.view???: , ???jsp.display-item.statistics.download???: