Detail View

Advanced Handheld Micro-Surgical System using an Hall Sensor and a Magnet Trocar for Retinal Microsurgery
Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

DC Field Value Language
dc.contributor.author Lee, Myung Ho -
dc.contributor.author Im, Jintaek -
dc.contributor.author Song, Cheol -
dc.date.accessioned 2025-02-03T22:40:15Z -
dc.date.available 2025-02-03T22:40:15Z -
dc.date.created 2024-12-08 -
dc.date.issued 2024-10-17 -
dc.identifier.isbn 9798350377705 -
dc.identifier.issn 2153-0866 -
dc.identifier.uri http://hdl.handle.net/20.500.11750/57863 -
dc.description.abstract Diseases affecting the retina, such as retinal detachment, diabetic retinopathy, and macular degeneration, are significant contributors to blindness globally, with a substantial risk of vision loss among those afflicted. Surgical treatment of these conditions is complex due to the delicate nature of retinal tissue and the challenges posed by involuntary hand movements. While existing methods aim to compensate for hand tremors using sensor-based systems, they are hindered by limitations in accurately tracking retinal surface movement during surgery, particularly in response to patient movements under anesthesia. To address these issues, this study proposes a novel handheld micro-surgical tool equipped with a 1-degree of freedom (DOF) mechanism and a 3-axis Hall sensor to mitigate physiological hand tremors effectively. By utilizing magnetic flux density measurements, the tool can pinpoint the position of a magnet embedded within the surgical instrument, enabling precise tremor compensation without reliance on a global coordinate system. The design incorporates a piezoelectric (PZT) linear actuator and a Hall sensor for compactness and sensitivity. Optimization of the magnet's dimensions through simulation ensures optimal sensor performance. Experimental validation using artificial and ex-vivo porcine eye models demonstrates the tool's effectiveness in reducing hand tremors, suggesting potential enhancements in the safety and accuracy of retinal surgeries. For the desired positions from 4000 μm to 1000 μm, the RMS error of the synthetic eye model and porcine eye decreased from 71.10 μm to 33.27 μm and 71.36 μm to 33.39 μm, respectively. © 2024 IEEE. -
dc.language English -
dc.publisher IEEE Robotics and Automation Society -
dc.title Advanced Handheld Micro-Surgical System using an Hall Sensor and a Magnet Trocar for Retinal Microsurgery -
dc.type Conference Paper -
dc.identifier.doi 10.1109/IROS58592.2024.10802576 -
dc.identifier.wosid 001433985300392 -
dc.identifier.scopusid 2-s2.0-85216472603 -
dc.identifier.bibliographicCitation Lee, Myung Ho. (2024-10-17). Advanced Handheld Micro-Surgical System using an Hall Sensor and a Magnet Trocar for Retinal Microsurgery. IEEE/RSJ International Conference on Intelligent Robots and Systems, 10621–10627. doi: 10.1109/IROS58592.2024.10802576 -
dc.identifier.url https://ras.papercept.net/conferences/conferences/IROS24/program/IROS24_ContentListWeb_4.html#thct7 -
dc.citation.conferenceDate 2024-10-14 -
dc.citation.conferencePlace AR -
dc.citation.conferencePlace Abu Dhabi -
dc.citation.endPage 10627 -
dc.citation.startPage 10621 -
dc.citation.title IEEE/RSJ International Conference on Intelligent Robots and Systems -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

송철
Song, Cheol송철

Department of Robotics and Mechatronics Engineering

read more

Total Views & Downloads