Detail View

DC Field Value Language
dc.contributor.author Guezzi, Nizar -
dc.contributor.author Lee, Sangheon -
dc.contributor.author Nam, Sangwoo -
dc.contributor.author Jung, Dongkyu -
dc.contributor.author Noman, Muhammad -
dc.contributor.author Seong, Hyojin -
dc.contributor.author Lee, Sanghoon -
dc.contributor.author Kim, Hoe Joon -
dc.contributor.author Yu, Jaesok -
dc.date.accessioned 2026-01-12T21:40:11Z -
dc.date.available 2026-01-12T21:40:11Z -
dc.date.created 2025-10-31 -
dc.date.issued 2026-02 -
dc.identifier.issn 0041-624X -
dc.identifier.uri https://scholar.dgist.ac.kr/handle/20.500.11750/59332 -
dc.description.abstract Three-dimensional (3D) imaging of vascular networks is essential for accurately diagnosing deep organ diseases. However, current ultrasound imaging methods are primarily limited to visualizing 2D cross-sections, which restricts the ability to evaluate the full structure of vascular networks. Although several 3D ultrasound techniques have been proposed to overcome this limitation, most struggle to achieve deep penetration and a wide field of view due to their high resource requirements. Row-column addressed arrays (RCAs) have emerged as a promising solution, enabling 3D imaging with significantly reduced hardware complexity. Nevertheless, the limited image quality achievable with RCAs has hindered their broader application. In this study, we propose a coded plane-wave-based, contrast-free 3D imaging system using RCAs for in vivo imaging of deep human vasculature. To validate the method, we imaged the liver and spleen of two healthy adult volunteers and successfully visualized vascular structures without contrast agent injection. Flow dynamics were captured at a frame rate of 27 Hz. Additionally, we demonstrated contrast-to-noise ratio (CNR) improvements of approximately 9 dB and 10 dB in the z-y and z-x planes, respectively, compared to non-coded excitation. This approach offers strong potential for in vivo 3D visualization and assessment of complex, deeply located vascular networks. -
dc.language English -
dc.publisher Elsevier -
dc.title Contrast agent-free 3D ultrasound deep-depth vascular imaging with a 2D row column addressed Array: In vivo human clinical feasibility study -
dc.type Article -
dc.identifier.doi 10.1016/j.ultras.2025.107805 -
dc.identifier.wosid 001576837000001 -
dc.identifier.scopusid 2-s2.0-105016098822 -
dc.identifier.bibliographicCitation Ultrasonics, v.158 -
dc.description.isOpenAccess FALSE -
dc.subject.keywordAuthor Deep vascular imaging -
dc.subject.keywordAuthor Plane waves -
dc.subject.keywordAuthor 3D flow imaging -
dc.subject.keywordAuthor Contrast free -
dc.subject.keywordAuthor Row Column Addressed -
dc.subject.keywordAuthor Coded excitation -
dc.subject.keywordPlus CODED EXCITATION -
dc.subject.keywordPlus MEDICAL ULTRASOUND -
dc.subject.keywordPlus CROSS-CORRELATION -
dc.subject.keywordPlus PART I -
dc.subject.keywordPlus SYSTEM -
dc.subject.keywordPlus SIGNALS -
dc.citation.title Ultrasonics -
dc.citation.volume 158 -
dc.description.journalRegisteredClass scie -
dc.description.journalRegisteredClass scopus -
dc.relation.journalResearchArea Acoustics; Radiology, Nuclear Medicine & Medical Imaging -
dc.relation.journalWebOfScienceCategory Acoustics; Radiology, Nuclear Medicine & Medical Imaging -
dc.type.docType Article -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

이상훈
Lee, Sanghoon이상훈

Department of Robotics and Mechatronics Engineering

read more

Total Views & Downloads