Detail View

DC Field Value Language
dc.contributor.author Guezzi, Nizar -
dc.contributor.author Lee, Sangheon -
dc.contributor.author Nam, Sangwoo -
dc.contributor.author Seo, Youngho -
dc.contributor.author Kim, Myeongchan -
dc.contributor.author Eom, Kisang -
dc.contributor.author Hyun, Jung Ho -
dc.contributor.author Yu, Jaesok -
dc.date.accessioned 2026-11-10T15:40:14Z -
dc.date.available 2026-11-10T15:40:14Z -
dc.date.created 2026-08-28 -
dc.date.issued 2027-01 -
dc.identifier.issn 0041-624X -
dc.identifier.uri https://scholar.dgist.ac.kr/handle/20.500.11750/61155 -
dc.description.abstract Delay-and-sum (DAS) beamforming is widely used in ultrasound flow imaging due to its computational simplicity; however, its high sidelobe levels significantly degrade image contrast. Coherence factor (CF) beamforming partially alleviates this limitation by emphasizing spatial coherence, yet residual incoherent energy remains and continues to impair image quality. In this study, we propose a dual-stage beamforming approach that integrates CF weighting with a frequency-domain filtering stage designed to discriminate and suppress incoherent energy while preserving coherent signal components. The proposed method, termed SCORE (Spectral COherence REfinement), introduces an additional coherence-based discrimination mechanism beyond conventional CF beamforming. Simulation experiments involving single-target, multi-target, and vascular scenarios demonstrate that SCORE achieves substantial sidelobe suppression while maintaining signal integrity. In vivo validation using an open-source contrast-enhanced rat brain and kidney dataset, as well as contrast-free human spleen further confirms improved flow detectability, reduced background noise, and enhanced power Doppler imaging performance, as evidenced by increases in SNR and CNR approaching 10 dB compared to CF and GCF beamforming. Overall, the SCORE beamformer provides a robust framework for high-contrast vascular ultrasound imaging, offering superior sidelobe and noise suppression relative to DAS, CF and GCF. To enhance computational efficiency, the beamforming pipeline was implemented on a graphics processing unit (GPU) using an optimized CUDA framework, achieving real-time beamforming performance with processing times below 30 ms per frame. -
dc.language English -
dc.publisher Elsevier B.V. -
dc.title SCORE beamforming: Spectral COherence REfinement for high-contrast ultrafast Doppler imaging -
dc.type Article -
dc.identifier.doi 10.1016/j.ultras.2026.108274 -
dc.identifier.wosid 001854287400001 -
dc.identifier.scopusid 2-s2.0-105047544283 -
dc.identifier.bibliographicCitation Ultrasonics, v.169 -
dc.description.isOpenAccess FALSE -
dc.subject.keywordAuthor Spectral beamforming -
dc.subject.keywordAuthor Ultrafast Doppler -
dc.subject.keywordAuthor Beamforming -
dc.subject.keywordAuthor Coherence factor -
dc.subject.keywordAuthor GPU-acceleration -
dc.subject.keywordPlus SPATIAL COHERENCE -
dc.subject.keywordPlus ULTRASOUND -
dc.citation.title Ultrasonics -
dc.citation.volume 169 -
dc.description.journalRegisteredClass scopus -
dc.relation.journalResearchArea Acoustics; Radiology, Nuclear Medicine & Medical Imaging -
dc.relation.journalWebOfScienceCategory Acoustics; Radiology, Nuclear Medicine & Medical Imaging -
dc.type.docType Article -
Show Simple Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

이상헌
Lee, Sang-Heon이상헌

Division of Mobility Technology

read more

Total Views & Downloads

???jsp.display-item.statistics.view???: , ???jsp.display-item.statistics.download???: