Cited time in webofscience Cited time in scopus

Full metadata record

DC Field Value Language
dc.contributor.author Seo, Hee Won -
dc.contributor.author Kim, Namju -
dc.contributor.author Kim, Sohee -
dc.date.accessioned 2020-07-17T04:47:45Z -
dc.date.available 2020-07-17T04:47:45Z -
dc.date.created 2020-05-29 -
dc.date.issued 2020-05 -
dc.identifier.issn 2072-666X -
dc.identifier.uri http://hdl.handle.net/20.500.11750/12085 -
dc.description.abstract This study presents the fabrication of three-dimensional (3D) microelectrodes for subretinal stimulation, to accommodate adjacent return electrodes surrounding a stimulating electrode. For retinal prosthetic devices, the arrangement of return electrodes, the electrode size and spacing should be considered together, to reduce the undesired dissipation of electric currents. Here, we applied the hexagonal arrangement to the microelectrode array for the localized activation of retinal cells and better visual acuity. To provide stimuli more efficiently to non-spiking neurons, a 3D structure was created through a customized pressing process, utilizing the elastic property of the materials used in the fabrication processes. The diameter and pitch of the Pt-coated electrodes were 150 μm and 350 μm, respectively, and the height of the protruded electrodes was around 20 μm. The array consisted of 98 hexagonally arranged electrodes, supported by a flexible and transparent polydimethylsiloxane (PDMS) base, with a thickness of 140 μm. Also, the array was coated with 2 μm-thick parylene-C, except the active electrode sites, for more focused stimulation. Finally, the electrochemical properties of the fabricated microelectrodes were characterized, resulting in the mean impedance of 384.87 kω at 1 kHz and the charge storage capacity (CSC) of 2.83 mC cm-2. The fabricated microelectrodes are to be combined with an integrated circuit (IC) for additional in vitro and in vivo experiments. © 2020 by the authors. -
dc.language English -
dc.publisher MDPI AG -
dc.title Fabrication of Subretinal 3D Microelectrodes with Hexagonal Arrangement -
dc.type Article -
dc.identifier.doi 10.3390/MI11050467 -
dc.identifier.scopusid 2-s2.0-85084923179 -
dc.identifier.bibliographicCitation Micromachines, v.11, no.5, pp.467 -
dc.description.isOpenAccess TRUE -
dc.subject.keywordAuthor retinal implant -
dc.subject.keywordAuthor subretinal stimulation -
dc.subject.keywordAuthor 3D electrodes -
dc.subject.keywordAuthor hexagonal electrodes -
dc.subject.keywordAuthor transparent base -
dc.subject.keywordPlus RETINAL GANGLION-CELLS -
dc.subject.keywordPlus BLIND SUBJECTS -
dc.subject.keywordPlus PROSTHESIS -
dc.subject.keywordPlus ACTIVATION -
dc.subject.keywordPlus BIOCOMPATIBILITY -
dc.subject.keywordPlus THRESHOLDS -
dc.citation.number 5 -
dc.citation.startPage 467 -
dc.citation.title Micromachines -
dc.citation.volume 11 -
Files in This Item:
000540761400017.pdf

000540761400017.pdf

기타 데이터 / 2.93 MB / Adobe PDF download
Appears in Collections:
ETC 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE