Detail View

Second-Derivative-Based Background Drift Removal for a Tonic Dopamine Measurement in Fast-Scan Cyclic Voltammetry
Citations

WEB OF SCIENCE

Citations

SCOPUS

Metadata Downloads

Title
Second-Derivative-Based Background Drift Removal for a Tonic Dopamine Measurement in Fast-Scan Cyclic Voltammetry
Issued Date
2022-08
Citation
Kang, Seong Tak. (2022-08). Second-Derivative-Based Background Drift Removal for a Tonic Dopamine Measurement in Fast-Scan Cyclic Voltammetry. Analytical Chemistry, 94(33), 11459–11463. doi: 10.1021/acs.analchem.2c01047
Type
Article
Keywords
PATHOPHYSIOLOGYADSORPTION
ISSN
0003-2700
Abstract
The dysregulation of dopamine, a neuromodulator, is associated with a broad spectrum of brain disorders, including Parkinson's disease, addiction, and schizophrenia. Quantitative measurements of dopamine are essential for understanding dopamine functional dynamics. Fast-scan cyclic voltammetry (FSCV) is the most popular electrochemical technique for measuring real-time in vivo dopamine level changes. Standard FSCV has only analyzed "phasic dopamine" (changes in seconds) because the gradual generation of background charging current is inevitable and is the primary noise source in the low-frequency band. Although "tonic dopamine" (changes in minutes to hours) is critical for understanding the dopamine system, an electrochemical technique capable of simultaneously measuring phasic and tonic dopamine in an in vivo environment has not been established. Several modified voltammetric techniques have been developed for measuring tonic dopamine; however, the sampling rates (0.1-0.05 Hz) are too low to be useful. Further investigation of the in vivo applicability of previously developed background drift removal methods for measuring tonic dopamine levels is required. We developed a second-derivative-based background removal (SDBR) method for simultaneously measuring phasic and tonic neurotransmitter levels in real-time. The performance of this technique was tested via in silico and in vitro tonic dopamine experiments. Furthermore, its applicability was tested in vivo. SDBR is a simple, robust, postprocessing technique that can extract tonic neurotransmitter levels from all FSCV data. As SDBR is calculated in individual-scan voltammogram units, it can be applied to any real-time closed-loop system that uses a neurotransmitter as a biomarker.
URI
http://hdl.handle.net/20.500.11750/17126
DOI
10.1021/acs.analchem.2c01047
Publisher
American Chemical Society
Show Full Item Record

File Downloads

  • There are no files associated with this item.

공유

qrcode
공유하기

Related Researcher

오용석
Oh, Yong-Seok오용석

Department of Brain Sciences

read more

Total Views & Downloads