Cited time in webofscience Cited time in scopus

Registration-free Minimally Invasive Surgery Without Preoperative Phase

Title
Registration-free Minimally Invasive Surgery Without Preoperative Phase
Author(s)
Bang, Sang-WonLee, Yun-JeongKee, HyeonwooPark, Sukho
Issued Date
2023-10
Citation
International Journal of Control, Automation, and Systems, v.21, no.10, pp.3313 - 3323
Type
Article
Author Keywords
robot-assisted point cloud acquisitionstiffness estimationsurface reconstructionRegistration-free
Keywords
TOTAL KNEE REPLACEMENTNAVIGATIONROBOTICS
ISSN
1598-6446
Abstract
Many types of research on robot-assisted minimally invasive surgery (RMIS) have been conducted, and its use in actual surgery is increasing. However, prior image information regarding the surgical target is required to generate a path for the surgical tool for RMIS. The image coordinate, target’s coordinate, and robot coordinate should be aligned through registration. However, errors are bound to occur during the image acquisition and registration. As the image acquisition time and registration time increase, the error between the patient and the coordinate information at the time of the actual operation increases due to the movement of the patient. To minimize these errors, this study proposes a registration-free approach to MIS without the preoperative phase in which a robot is used to directly contact the target to obtain a point cloud and reconstruct the shape information of the target. Using the position-based impedance and constraint controls for the remote center of motion (RCM) of the robot for MIS, the position information of the target can be acquired in the form of a point cloud without damage. Further, by converting the obtained point cloud into a mesh form using the Point2Mesh deep learning algorithm, it is possible to reconstruct the area where the position information is insufficient because there is no contact among the target areas. The process could obtain the coordinates within 3 min for the phantom. After a deep learning process of about 10 min, a surgical path using a robot could be generated. The reconstruction accuracy showed a RMSE of up to 0.35 mm. Additionally, this method enables the acquisition of stiffness information of the target, unlike using the prior image information. Therefore, it is expected that a stiffness overlay can be constructed and used for the diagnosis and treatment of targets. © 2023, ICROS, KIEE and Springer.
URI
http://hdl.handle.net/20.500.11750/46665
DOI
10.1007/s12555-022-0916-8
Publisher
제어·로봇·시스템학회
Related Researcher
  • 박석호 Park, Sukho
  • Research Interests Biomedical Micro/Nano Robotics; Biomedical Devices and Instruments
Files in This Item:

There are no files associated with this item.

Appears in Collections:
Department of Robotics and Mechatronics Engineering Multiscale Biomedical Robotics Laboratory 1. Journal Articles

qrcode

  • twitter
  • facebook
  • mendeley

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE